Model C707 Troubleshooting Guide
Section 8 Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
1. No product is being
dispensed with draw valve
open and the machine in
the AUTO mode.
a. Freeze- up in mix inlet
hole.
a. Call service technician to
adjust the mix hopper
temperature.
---
b. Beater motor out on reset. b. Reset the freezer .
12
c. The beater is rotating
counterclockwise from the
operator end.
c. Contact service technician
to correct rotation to
clockwise from operator
end.
---
d. The circuit breaker is off
or the fuse is blown.
d. Turn the breaker on, or
replace the fuse.
---
e. There is inadequate mix in
the mix hopper.
e. Fill the mix hopper with
mix.
20
2. The product is too stiff. a. The viscosity needs
adjustment.
a. Contact service
technician.
---
3. The product is too soft. a. Viscosity needs
adjustment.
a. Contact service
technician.
---
b. Not enough air space
around unit. (Air cooled
units)
b. Allow for adequate air flow
across the condenser .
1/ 6
c. W orn scraper blades. c. Replace regularly.
27
d. Dirty condenser (A/C) d. Clean monthly.
24
e. Mix is out of date. e. Use only fresh mix.
---
f. Loss of water . (W/C) f. Locate cause of water
loss and correct.
24
4. The mix in the mix hopper
is too cold.
a. The temperature is out of
adjustment.
a. Call service technician to
adjust the mix hopper
temperature.
---
5. The mix in the mix hopper
is too warm.
a. The temperature is out of
adjustment.
a. Call service technician to
adjust the mix hopper
temperature.
---
b. The mix hopper cover is
not in position.
b. Place the cover in
position.
20
c. The MIX REF light is not
lit.
c. Press the MIX REF key.
11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C707 and is the answer not in the manual?

Taylor C707 Specifications

General IconGeneral
Power208-230V, 60Hz, 1Ph
Minimum Clearance6" on both sides
Water Inlet3/8" FPT (Water Cooled)
Water Outlet3/8" FPT (Water Cooled)
Separate Hopper RefrigerationMaintains mix below 41ºF (5ºC) during Auto and Standby modes.

Related product manuals