28
Controls and Systems
Model SB25
Step 5
Disconnect and remove the water valve connector
from the Dispense PCB.
Step 6
Remove the water inlet tube from the manifold
assembly.
Step 7
Remove the manifold mounting screws located in
the Dispense PCB mounting box.
Figure 35
Step 8
Remove the manifold.
Figure 36
Cane Dispense
______________________________
The Cane Dispense supplies liquid cane to the
blender pitcher during drink dispensing.
Troubleshooting
If cane is not dispensed or an incorrect amount is
dispensed, check the following:
Step 1
Make sure the cane source is present and has an
adequate supply.
Step 2
Make sure the cane line is connected to the rear of
the system and is free from kinks.
Step 3
Check the system for leaks.
Disassembly
Step 1
Turn off the power switch and unplug the
power cord.
Step 2
Remove the ice hopper and lid. (See page 17.)
Step 3
Remove the Drive Board. (See page 18.)
Step 4
Remove the main drain assembly. (See page 19).
Step 5
Remove the Dispense PCB cover.
Step 6
Remove the cane pump connector from the
Dispense PCB.
Figure 37