9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid Gas
FMA-09CHSD/DVI FMA-12CHSD/DVI 1/4 3/8
FMA-09CRD/DVI(Q4) FMA-12CRD/DVI(Q4) FMA-09D5RD/DVI FMA-09D5RD/DVI 1/4 3/8
FMA-18CRD/DVI(Q4) FMA-18D5RD/DVI 1/4 1/2
Mo
de Standard length: m
Refrigerant piping
Max. length: m
A
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
9K
3.0 15 20g/m
12K
3.5 15 20g/m
18K
5.0 15 30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps Wire Size
5 AWG21/0.75 mm2
10 AWG18/1.0 mm2
13 AWG15 /1. 5 mm2
18 AWG14/1.6 mm2
25 AWG12/2.0 mm2
30 AWG10/2.5 mm2
Outdoor unit
In door uni t
Pipe length is
15 meters Max.