TCL U-MATCH-R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
91
3.3.11
P6---Overheating protection on Cooling mode
On Cooling or Dry mode, when ODU condenser coil temperature OPT≥65(149) , MCU will switch off
outdoor unit and show P6 failure code.
Display P6
ODU fan motor
No
works normal?
Fan motor
broken?
Yes
Replace fan motor
Yes
No
No
P6 disappear?
Yes
Sensor loosing
from connector?
Re-connect sensor
P6 disappear?
Yes
Yes
No
The sensor open
No
or short circuit?
Yes
Replace OPT sensor
Yes
P6 disappear?
No
Replace ODU PCB
End