TCL U-MATCH-R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
91
3.3
Trouble Shooting
3.3.1
E0 ---IDU & ODU communication failure
Start
Display E0
If IDU wiring
connection correct ?
No
Check and re-
No
connect
E0 disappear?
Yes
Yes No
Check communication
wiring and the connection,
in good condition?
No
Replace/ re-
connect
E0 disappear?
Yes
No
Yes
No
ODU wiring
Connection correct?
Yes
Check and re-
connect
E0 disappear?
Yes
No
Check voltage from No
IDUODU terminal btw
L,N. is there
220-240V?
Yes
Check the power
supply connection
Replace or
reconnect
No
E0 disappear?
Yes
Yes
Is the ODU PCB
LED4 ON?
No
ON
constantly
Replace ODU PCB
End
Replace IDU
PCB