TCL U-MATCH-R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
103
3.3.15
J6---Module temperature protection.
IPM overtemperature protection, when IPM temperature more than 95, it will show J6.
Display J6
IPM well contact
No
to heat sink?
Any dust or gap btw
IPM & heat sink?
Yes
Yes No
Check the screw
fully fasten?
No
Fix the screw
Yes
F7 disappear?
No
Yes
ODU cooling system
abnormal? Compressor
with big running current?
(18,24K:7-9A,
30,36K(1-Phase):11-14A
36,42K(3-Phase):16-19A)
Yes
Low pressure normal?
0.8-1.2Mpa
No
Yes
No
Is the 2/3way valve
fully opened?
No
Open the valve
Yes
Yes
Capillary blocked?
No
F7 disappear?
No
Replace capillary
Yes
End
Yes
Clean condenser /
evaporator
Condenser /
evaporator dirty?
No
IPM temperature
circuit abnormal?
Clean or adjust the gap
btw IPM and heat sink
Replace ODU PCB
End