CHAPTER 2 SPECIFICATIONS
2.1 SPECIFICATIONS: 200W/400W Series
ZUP20-
20
ZUP20-
10
ZUP10-
40
ZUP10-
20
ZUP6-
66
ZUP6-
33
ZUP60-
7
0 ~ 7
0 ~ 12
ZUP60-
3.5
0 ~ 3.5
0 ~ 6
216 432 210 420
ZUP36-
12
ZUP36-
6
0 ~ 36
0 ~ 60
ZUP120-
3.6
ZUP120-
1.8
ZUP80-
5
ZUP80-
2.5
V
A
W
-
-
mV
mV
mS
-
-
mS
mS
mS
-
-
mA
-
-
-
-
-
-
V
-
-
-
-
-
-
A
-
-
%
A
MODEL
OUTPUT VOLTAGE (*1)
OUTPUT CURRENT (*2)
RATED OUTPUT POWER
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
RIPPLE
RECOVERY TIME (*4)
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwid
th)
(pk to pk 20MHz Bandwid
th)
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwid
th)
INPUT VOLTAGE (*8)
INPUT CURRENT (*6)
INPUT CURRENT HARMONICS
POWER FACTOR (TYP)
EFFICIENCY (*6)
INRUSH CURRENT (*7)
100/200V
VOLTAGE
CURRENT
STATUS
UP PROGRAMMING RESPONSE TIME
FULL LOAD
NO LOAD
RESOLUTION
ACCURACY
RESOLUTION
ACCURACY
VOLTAGE
CURRENT
CONSTANT
VOLTAGE
CONSTANT
CURRENT
DOWN
PROGRAMMING
RESPONSE TIME
PROGRA-
MING (*3)
DISPLAY
OVERVOLTAGE PROTECTION
(*5)
HOLD UP TIME
OUTPUT PROTECTIONS
INPUT
10
5.6 / 2.7
5.3/2.6
80 / 84
82 / 86
15
5.6 / 2.7
4.9/2.4
80 / 84
83 / 87
0 ~ 20
30
5.6 / 2.7
79 / 83
0 ~ 40
50
5.6 / 2.7
79 / 82
0 ~ 66
0.005% +2mV (*10)
0.005% +4mV
0.005% +1mV (*1
1)
0.005% +2mV
5
50
30ppm/ C from rated volt
age following 30-minute warm-up
O
0.01% +2mV change in output over 8-hour interval under const
ant line, load and ambient
temperature following 30-minute warm-up
50
50
100
5.6 / 2.7
74 / 77
15
15
15
15
15
15
15
5
5
5
5
5
2.9 / 1.4
2.9/1.4
75 / 79
78 / 82
7.5
2.9 / 1.4
2.6/1.3
76 / 80
78 / 82
0 ~ 10
15
2.9 / 1.4
74 / 78
0 ~ 20
25
2.9 / 1.4
73 / 77
0 ~ 33
198 396 200 400 200 400
50
3.0 / 1.5
69 / 72
15 / 30 15 / 30 15 / 30 15 / 30
15 / 30
15 / 30
15 / 30
250
0 - 7.5
1
350
0 -13
0.5
400
0 - 24
0.2
0.01% + 5mA for load voltage change equal to unit volt
age rating , constant input voltage.
0.01% +2mA from 85-132VAC or 170-265VAC, constant load
20mS at 100V/200VAC, rated output volt
age and output current
100ppm/ C from rated current following 30 minute warm-up
O
Better than 0.028% of rated output volt
age
0.02% + 5mV 0.02% + 8mV 0.02% + 12mV 0.02% + 26mV 0.02% + 35mV
0.4% + 40mA
Better than 0.03% of rated output current
0.02% +5mA change in output over 8-hour interval under const
ant line, load and ambient
temperature following 30 minute warm-up
3 digits (6V, 20V, 36V, 60V, 80V) 3.5 digits (10V, 120V) accuracy: 0.2% +/- 2 digit
s
3 digits accuracy: 0.5% +/- 3 digit
s
CV/CC, Alarm, Fold, Local/Remote, ON/OFF
Over Voltage, Over Temperature, Foldback
85 ~ 265VAC Continuous, 47 ~ 63Hz
Complies with EN61000-3-2, Class
A
0.99 at 100/200VAC, 100% Load
500
0 - 40
0.02%+50mV
0.4%+
0.4%+
0.4%+
0.4%+
15mA
30mA
10mA
20mA
0 - 88
0 - 132
0.02%+80mV
0.2
750
0 - 66
0.2
100
0 ~ 6
0 ~ 10
0 ~ 20
0 ~ 1.8
0 ~ 5
20
0 ~ 3.6
0 ~ 2.5
20
200
70
60
0.2
800
400
80
80
0.2
1000
216 432
0 ~ 80
0 ~ 120