Outlines the contents of the user manual.
Overview of Genesys power supplies, models, features, and options.
Covers multi-unit systems, serial control, analog programming, parallel operation, and output connections.
Details available accessories like cables and hardware.
Details cooling methods and mechanical construction of the power supplies.
Details the voltage, current, and power ratings for all models.
Specifies input voltage, current, and efficiency characteristics.
Parameters for Constant Voltage operation mode.
Parameters for Constant Current operation mode.
Specifies analog programming and monitoring capabilities.
Accuracy and resolution for programming and readback.
Describes over-voltage, under-voltage, and foldback protection functions.
Details front panel controls, displays, and indicators.
Specifies operating temperature, humidity, and altitude limits.
Provides mechanical specifications like weight and dimensions.
Lists applicable safety and EMC standards.
Lists typical, non-warranted performance characteristics.
Shows dimensional drawings of the power supply unit.
Overview of the installation chapter.
Steps for preparing the power supply for operation.
Instructions for inspecting the unit upon unpacking.
Steps for installing the power supply into a rack, including brackets and slides.
Guidelines for proper placement and cooling of the unit.
Specifies the required AC input voltage and frequency.
Specifics on AC input connectors and wire connections for different models.
Steps to verify proper operation after initial setup.
Guidelines for selecting wire and making load connections.
Explanation and configuration of local and remote sensing methods.
Instructions for safely repacking the unit for shipment.
Overview of front and rear panel components.
Details of all front panel controls, indicators, and displays.
Details of all rear panel connections and controls.
Describes SW1 switch functions and how to reset it.
Details of the J1 connector for programming and monitoring.
Overview of local operation modes.
Explains Constant Voltage (CV) and Constant Current (CC) operating modes.
Describes the automatic transition between CV and CC modes.
Details OVP function, setting, and resetting.
Details UVL function, setting, and behavior.
Details Foldback protection function, setting, and resetting.
Controls for enabling/disabling the power supply output.
Using J1 connector for output shut-off control.
Using J1 connector for output enable/disable control.
Indicates the current operating mode (CV or CC).
Indicates the power supply status and fault conditions.
Configuration of start-up modes.
Protection against overheating.
Stores power supply parameters for recall.
Connecting units in series to increase output voltage or for +/- outputs.
Configuring units for parallel operation to increase current capability.
Connecting multiple units for synchronized shutdown on fault.
Enabling/disabling front panel controls to prevent accidental changes.
Introduces remote analog programming capabilities.
How to select between local and remote analog control.
Indicates the analog programming mode.
Programs output voltage and current limit remotely.
Programs output voltage and current limit using resistors.
Monitors output voltage and current remotely.
Describes operation via serial communication port.
Covers default settings, address, interface, and baud rate selection.
Operation when the port is in Local mode.
Front panel control behavior in Remote mode.
Details the rear panel connector for RS232/485 interface.
Procedures for connecting single or multiple units to the bus.
Details data format, addressing, error handling, and protocol.
Lists and describes programming and command error codes.
Overview of available commands and their categories.
Commands for initializing the power supply.
Commands for retrieving unit identification.
Commands for controlling output voltage and current.
Commands that affect all units on the bus.
Commands for reading power supply status and registers.
Explains the structure and function of status, error, and SRQ registers.
Introduces the isolated analog programming option.
Specs for 0-5V/0-10V and 4-20mA isolated programming options.
Describes the connector for isolated programming.
Procedures for setting up and using isolated programming options.
Overview of maintenance, calibration, and troubleshooting.
Information on returning units for warranty repair.
Guidelines for periodic cleaning and care.
States no internal adjustments or calibration are required.
Information on contacting service for repairs.
A guide to diagnose and resolve common power supply issues.
Lists fuse ratings for 750W and 1500W models.
| Output Voltage Range | 0 to 40 V |
|---|---|
| Output Current Range | 0 to 38 A |
| Input Voltage Range | 85 to 265 VAC |
| Input Frequency | 47 - 63 Hz |
| Power Rating | 1.5 kW |
| Cooling | Fan |
| Operating Temperature | 0 to 50 °C |