EasyManua.ls Logo

Teac X-3R - ELECTRICAL ADJUSTMENT AND CHECKS; POWER SUPPLY CHECK; MONITOR AND OUTPUT LEVEL CHECKS

Teac X-3R
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
X-3R
2-13
LUBRICATION
Oiling
is
needed
after
every
1,000
hours
of
operation
or
once
a
year
if
the
deck
is
used
infrequently.
TEAC
spindle
oil
(from
TEAC
TZ-255
oil
kit),
Mobil
D.T.E.
Oil
Light,
and
similar
types
of
oil
are
recommended,
Lubrication
is
normally
not
necessary
except
at
the
points
shown.
1.
Place
the
deck
in
a
horizontal
position.
2.
Apply
a
few
drops
of
oil
to
the
respective
spindles
shown,
except
the
capstan
and
the
reel
motors,
Spread
the
oil
evenly
on
the
spindle
surfaces
using
a
cotton
cloth
or
similar
applicator.
3.
For
the
capstan
and
reel
motors,
apply
a
few
drops
to
the
indi-
cated
positions
but
do
not
spread
the
oil.
4.
After
oiling
all
points,
operate
the
deck
fer
1
to
2
hours
until
the
oil
is
thoroughly
absorbed.
Fig.
2-15
3
ELECTRICAL
ADJUSTMENT
AND
CHECKS
NOTES:
1,
Clean
and
demagnetize
the
entire
tape
path
prior
to
3-1
POWER
SUPPLY
CHECK
making
any
adjustments
or
checks,
2.
Make
sure
that
the
deck
is
properly
set
for
the
volt-
age
in
your
area.
3.
Adjustments
and
checks
are
generally
done
in
order
of
L-ch,
then
R-ch.
Double
reference
numbers
in-
dicate
L-ch/R-ch,
(Example:
R121/R221)
R
&
P
AMPL
PCB
4.
0B
is
referenced
to
0.775
V.
If
an
AC
voltmeter
is
used
which
references
0
dB
to
1
V,
appropriate
com-
pensation
must
be
made,
5.
An
AC
voltmeter
with
an
input
impedance
of
1M
ohms
or
more
must
be
used.
6.
In
the
charts,
instruction
in
the
MODE/INSTRUC-
TION
column
at
each
step
is
continued
from
pre-
vious
step
indication
unless
specified
here.
1.
Connect
a
DC
voltmeter
to
pin
15
of
U102
on
the
R
&
P
AMPL
PCB.
2.
The
DC
voltage
shoud
be
+12
V.
(See
Fig.
3-1)
DC
VOLTMETER
3-2.
MONITOR
PERFORMANCE
Deck
settings:
MONITOR
sw.:
SOURCE
MODE/
SIGNAL
ADJUST
INSTRUCTION
SOURCE
(or
CHECK)
Suyrar
REMARKS
MIC
cont:
MIN
rare,
LINE
cont:
MAX
pia
an
na
R123/R223
+1
dB
(0.869
V)
Par
g
min,
input
OUTPUT
cont:
MAX
.
OUTPUT
cont.
(L/R)
Specified
if
channels
do
position
for
1.
MONITOR
not
match,
re-
—5
dB
(436
mV)
OUTPUT
control
output
adjust
R123/
R223
to
corres-
pond
to
the
lower
OUTPUT,
IMPORTANT:
After
setting
OUTPUT
control
(L/R),
always
leave
in
specified
position.
OUTPUT
cont:
400
Hz/—12
dB
LINE
cont
Specified
position
Spec.
position
(195
mV)
mts
for
LINE
control

Related product manuals