- 29 -
EO3-11084
MA-1350-1 SERIES
Address : 5
([AT/TL] Key Function)
0
Initial SET Bit Nos.
Your Selection
Supplementary Description for Address 5:
Bit 1 & 2: If both RESET or both SET, the [AT/TL] key functions as tender and total key.
Bit 8: SET status .................... When the [AT/TL] key is operated, the SLIP lamp will flicker to prohibit
all the operations (including control lock position change and cashier
key change) other than the validation print. The status of this bit is
applicable in the REG or MGR position, and is not applicable in the
“ - ” position. When the [AT/TL] key is depressed, the drawer will not
open. It will open when the [VALIDATE] key is depressed.
1 Total Function
2 Tender Function
3 to 7
--vacant--
8 Validation Compulsory
Content
Bit
No.
Selective Status
RESET
SET
Follow Bit 1 status.
TOTAL FUNC-
TION only
TENDER FUNC-
TION only
Follow Bit 2 status.
NOT COMPULSORY
COMPULSORY