3. OPERATION MODE
In this submenu, the user can view, edit or set the operation mode in a given zone. It is also possible edit weekly schedules
here.
The user may set 6 weekly schedules in a given zone: 1 local schedule and 5 global schedules. The schedule temperature
settings are common for heating and cooling; the type of schedule selected in a given mode is saved separately.
Local schedule - it is a weekly schedule assigned to a given zone only. It may be edited freely
Global schedule 1-5 - these schedules have the same settings for all zones.
Constant temperature – this function enables the user to define a separate pre-set temperature that will apply in
the zone regardless of the time of the day.
With time limit – this function is used to configure the pre-set temperature which will apply for a pre-defined period
of time. When the time is over, the pre-set temperature in a given zone depends on the previously set mode
(schedule or constant without time limit).
4. USER SETTINGS
4.1. HOUSE HEATING
This function enables the user to activate/deactivate house heating.
4.2. HEATING
ON – this function enables the user to include/ exclude the zone in/from the heating algorithm.
Schedule settings – this function enables the user to choose the schedule which will apply in a zone (local schedule,
global schedule 1-5) during heating , if the zone operation is based on a schedule.
Constant temperature – this function enables the user to define a separate pre-set temperature that will apply in
the zone during heating, if the zone operation is based on a constant temperature.
4.3. COOLING
ON - this function enables the user to include/ exclude the zone in/from the cooling algorithm
Schedule settings – this function enables the user to choose the schedule which will apply in a zone (local schedule,
global schedule 1-5) during cooling , if the zone operation is based on a schedule.
Constant temperature – this function enables the user to define a separate pre-set temperature that will apply in
the zone during cooling, if the zone operation is based on a constant temperature.
Humidity protection– this function is used to protect the floor against dewfall (condensation). If the humidity in a
given zone is higher than ‘Max humidity’ value defined in the fitter’s menu, cooling will be disabled in this zone.
4.4. TEMPERATURE SETTINGS
This function enables the user to define pre-set temperatures for three operation modes (Comfort mode, Economical mode
and Holiday mode).