4.17. FACTORY SETTINGS
This parameter is used to restore the factory settings of a given valve.
5. HUMIDITY PROTECTION
If the current humidity value is higher than the pre-set maximum humidity (fitter’s menu -> protection - humidity -> Maximum
humidity), cooling in the given zone will be disabled. The function is activated for particular zones (Zones -> Zone 1 -> User
settings -> Cooling -> Humidity protection).
Additionally, through a two-state humidity sensor (the input located next to the heating / cooling) it is possible to disable
cooling altogether in the master controller, in all the zones where the humidity protection option is on. (Zones -> Zone 1 ->
User settings -> Cooling -> Humidity protection). The function is active only when the Humidity protection option is enabled
(fitter’s menu -> protection - humidity -> ON).
6. FACTORY SETTINGS
Once the Factory settings option is activated, all customized settings are lost and replaced with the manufacturer's settings.
IX. SCHEDULE SETTINGS
Once the schedule has been selected (Menu -> Zones -> Zone 1-8 -> Weekly control), the user may select, view and edit a
given schedule.
Schedule view screen:
1. Time periods.
2. Pre-set temperature for time perdiods.
3. Pre-set temperaturę outside time periods.
4. Days when the above settings will apply.
Follow these steps to configure a schedule:
Select the part of the week when the daily schedule will apply (part 1
or part 2).
In order to assign days to a given part of the week, follow the steps:
1
2
3
4