Hysteresis - This function is used to set the hysteresis of pump activation temperature.
Sensor This function is used to select the sensor which will provide temperature readings for additional heat
source activation/deactivation.
Room regulator This function is used to select the room regulator which will influence additional heat source
operation. When the pre-set temperature of this regulator is not reached, the controller will enable the
additional heat source regardless of current temperature of the selected sensor.
Example:
Part of the heating system is handled by fireplace and gas boiler. CH boiler is connected to voltage-free contact and the
fireplace temperature is read from sensor T4 (CH). The pump will be enabled when the sensor temperature does not
exceed <activation threshold>. The pump will be disabled when the room temperature is reached or when T4 sensor
exceeds <activation threshold>.