Room regulator function - This parameter defines the influence of room regulator on valve operation.
Closing - When room regulator sends a signal informing that the pre-set room temperature has been
reached, the controller will close the main valve.
Room temperature reduction - When room regulator sends a signal informing that the pre-set room
temperature has been reached, the pre-set valve temperature will be reduced by the value defined in this
parameter (TECH regulator algorithm calculates room temperature reduction on the basis of room
temperature difference).
Pump deactivation – When room regulator sends a signal informing that the pre-set room temperature has
been reached, the controller will disable the pump.
NOTE
Function available only for built-in valves.
7.5. PUMP ACTIVATION
This option is used to select pump operation mode:
Always OFF - the pump is inactive all the time, the
regulator controls only valve operation.
Always ON - the pump operates all the time,
regardless of temperatures.
Always above the treshold - the pump is switched on
above pre-set activation temperature. Settings
range: 1°C to 80 °C.
7.6. MAXING VALVE SETTINGS
Weather-based control - For the function of weather
control to be active, the external sensor mustn't be
exposed to sunlight or influenced by the weather
conditions. After it is installed in an appropriate place,
weather control function needs to be activated in the
controller menu.
For the valve to operate correctly, the user defines
the pre-set temperature (behind the valve) for 4
intermediate external temperatures: -20°C, -10°C, 0°C
and 10°C.