7.7. CH SENSOR SELECTION
This option is used to select the sensor which should serve as CH sensor. It may be any sensor which is connected to the
controller.
NOTE
Always make sure if proper sensor is selected to ensure correct pump operation.
7.8. PROTECTIONS
CH boiler protection - this function serves to prevent the
hazardous growth of CH boiler temperature. The user
sets the maximum acceptable CH boiler temperature. In
case of the hazardous growth in temperature, the valve
begins to open in order to cool the CH boiler down. This
function is activate by default.
NOTE This option is not available for floor valves.
Return protection - this function is used to set CH boiler
protection against too cool water returning from the
main circulation, which could cause low-temperature
boiler corrosion. The return protection involves closing
the valve when the temperature is too low, until the
short circulation of the boiler reaches appropriate
temperature.
NOTE
To ensure effectiveness of this protection, it is necessary to activate the valve in the heating circulation menu.
7.9. VELVE DEACTIVATION
Once this function is selected, valve operation depends on weekly control settings and external temperature.
Weekly control - once this function is selected, the user may activate/deactivate weekly operation schedule and
define the time when the valve will be closed.
NOTE
Operation schedule in <Weekly control> may be defined as ‘weekly control ON/OFF’, which is different from
Weekly control presented elsewhere in the menu. Weekly control is described in detail in section VIII.