EasyManua.ls Logo

Technica Engineering 1000Base-T1 - GENERAL EMC TEST INFORMATION; EMC Test Cases and Warnings; Emission Testing and Return Policy

Technica Engineering 1000Base-T1
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1000BASE-T1 MediaConverter EMC User Manual
28
7 GENERAL EMC TEST INFORMATION
Testcases:
We test our EMC products with 350 V/m in a Stripline setup from 1 MHz to 1 GHz. The
devices are not damaged in this setup.
There will be no Link Drop on 100BASE-T1 or 1000BASE-T1.
Warning: At frequencies below 1 MHz immunity must be tested at a maximum of
100V/m. Otherwise the devices will be permanently damaged!
We test our EMC products with 200 mA in a BCI substitution setup from 1 MHz to 1
GHz. The devices are not damaged in this setup.
There will be no Link Drop on 100BASE-T1 or 1000BASE-T1.
Warning: BCI closed loop method is not allowed for 100BASE-T1 or 1000BASE-T1
products. This test would permanently damage any device (independent of the vendor
of device) if user’s generator is strong enough.
Warning: At frequencies below 1 MHz the immunity must be tested at a maximum of
40 mA. Otherwise the devices will be permanently damaged!
Emission:
We test our EMC devices according to automotive emission standards. Since
standards and expectations vary, we grant a 4 week return period. You can test our
device according to your needs in your chamber. If you are not satisfied with the result,
you can return the devices and get refunded.

Related product manuals