NOTES
3:
Keep
good
condition,
set
lever
switches
and
controls
in
the
following
positions,
unless
otherwise
specified.
@
Make
sure
heads
are
clean.
©
Tape
selector:
Auto
position
e
Make
sure
capstan
and
pressure
roller
are
clean.
@
Input
level
controls:
Maximum
©
Judgeable
room
temperature:
20£5°C
(68£9°F)
©
Output
level
control:
Maximum
@
Dolby
NR
switch:
OUT
ITEM
MEASUREMENT
&
ADJUSTMENT
®
Head
position
(The
head
adjusting
plate
is
provided
to
adjust
the
tape
touch
of
screw
(A)
‘ad
Adjusting
Plate
adjustment
the
head
in
cue
or
review
mode).
Oe
me
Condition:
1.
Press
the
playback
button
and
pause
button.
*
Playback
and
pause
mode
2.
Measure
the
space
between
the
pinch
roller
and
the
capstan.
Na
~
Pressure
Roller
|
Standard
value:
0.5+0.3mm
Space
(adjustable)
.
If
the
measured
value
is
not
within
the
standard
value,
untighten
screw
(A),
and
slide
the
head
adjusting
plate
in
the
direction
Fig.
31
of
arrow
(B)
for
adjustment.
©
Head
azimuth
.
Test
equipment
connection
is
shown
in
fig.
32.
i
a
FN
adjustment
.
Playback
azimuth
tape
(QZZCFM
8kHz).
(0)
S
Condition:
.
Adjust
record/playback
head
angle
adjustment
screw
(B)
tape
Playback
mode
VTVM
Oscilloscope
*
Playback
mode
in
fig.
33
so
that
output
level
at
LINE
OUT
becomes
Fig.
32
*
Normal
m
maximum.
E
;
aa
age
.
Measure
both
channels,
and
adjust
levels
for
equal
output.
al
daa
paedin
_
After
adjustment
lock
head
adjustment
screw
with
lacquer.
*VTVM
*
Oscilloscope
*
Test
tape
(azimuth)
8)
+++
QZZCFM
Fig.
33
@
Tape
speed
Tape
speed
accuracy
Condition:
1.
Test
equipment
connection
is
shown
in
fig.
34.
Record/playback
head
LINE
OUT
*
Playback
mode
2.
Playback
test
tape
(QZZCWAT
3,000Hz),
and
supply
*
Normal
tape
mode
playback
signal
to
frequency
counter.
Equipment:
.
Measure
this
frequency.
Test
tape
+
Digital
electronic
counter
or
.
On
the
basis
of
3,000Hz,
determine
value
by
following
Fig.
34
frequency
counter
formula:
*
Test
tape
++
QZZCWAT
Tape
speed
accuracy
=
aD
Playback
mode
Digital
electric
counter
f—3,000
3,000
.
Take
measurement
at
middle
section
of
tape.
100
(%)
where,
f=measured
value
Standard
value:
+1.5%
Adjustment
method
1.
Playback
the
test
tape
(middle).
2.
Adjust
so
that
frequency
becomes
3,000
Hz.
3.
Tape
speed
adjustment
VR
shown
in
fig.
25.
Tape
speed
fluctuation
Make
measurements
in
same
manner
as
above
(beginning,
middle
and end
of
tape),
and
determine
the
difference
between
maximum
and
le
values
and
calculate
as
follows:
Tape
speed
fluctuation
=—
-~~—
X
100
(%)
f1=maximum
value,
f2=minimum
value
fe
aur
000
Standard
value:
1%