EasyManua.ls Logo

Technics RS-M7

Technics RS-M7
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Front-Loading
Vartical
Hold
Stereo
Cassette
Deck
with
Full
Auto-Stop
Mechanism
and
Dolby
NR
DO
[acevsverew]
RS-631
MECHANISM
SERIES
Specifications
Power
requirement:
Power
consumption:
Motor:
Track
system:
Tape
speed:
Wow
and
flutter:
Frequency
response:
Signal-to-noise
ratio:
For
All
European
areas
except
United
Kingdom
AC;
110/220
V,
50/60
Hz
For
Asia,
Latin
America,
Middle
East
and
Africa
areas
AC;
110/125/240V,
50/60
Hz
For
Australia
AC;
240V,
50/60
Hz
10W
Electronic
control
DC
motor
A-track
2-channel
stereo
recording
and
playback
4
8cm/s
0.08%
(WRMS),
+0.20%
(DIN)
CrO2/Fe-Cr
tape;
30
~
15,000
Hz
30
~
14,000
Hz
(DIN)
30
~
14,000
Hz
30
~
13,000
Hz
(DIN)
Dolby
NR
in:
66
dB
(above
5kHz)
Dolby
NR
out;
56dB
(signal
level
=max.
record-
ing
level,
Fe-Cr/CrO2
type
tape)
Normal
tape;
ervice
Manual
Fast
forward
and
rewind
time:
Input
:
Output:
Rec/pb
connection:
Bias
frequency
:
Head
:
Dimensions
:
Weight
:
Specifications
are
subject
to
change
without
notice.
*
‘Dolby’
and
the
double-D
symbol
are
trademarks
of
Dolby
Laboratories.
‘Technics
ORDER
NO.
ARD-7903018C
Cassette
Deck
RS-M7
(
Silver
iat
Black
Type
SUUORED-OUORED-CONEED-cORDEO-CROGED-COEERD-CERUED~
CDE
EOD
-cERODE~
CODED
08080
-C8CREr~
CURED
=~
cORNdr-cebeND-ceneer-cebeer-c8beeny
ry
This
is
the
Service
Manual
for
the
following
areas.
[D]
..---.---
For
All
European
areas
except
United
Kingdom.
[N]
«+--+
+.
For
Asia,
Latin
America,
Middle
East
and
Africa
areas.
teteenens
For
Australia.
= =
Topnene-chneer-cnaner-cbaeen-sanenr-coenee-cODeannonReer-eoeOnn-cODNSn-cONGdr=-ceeee~
seen
cnnnan-sppene-cEseno-ceeene-cnenae®
Approx.
86
seconds
with
C-60
cassette
tape
MIC;
sensitivity
0.25
mV,
input
impedance
33
K2
applicable
microphone
impedance
4002
~
10
KQ
LINE;
sensitivity
60
mV,
input
impedance
47
KQ
LINE;
output
level
420
mV,
output
impedance
1KQ
or
less,
load
impedance
22
KQ
over
HEADPHONE
;
output
level
65
mV,
load
impedance
82
5P
DIN
type;
input
sensitivity
0.25
mV,
impedance
8.2
KQ
output
level
420
mV,
impedance
4.7
KQ2
80
kHz
2-head
system;
l-super
permalloy
head
for
record/playback
1-double-gap
ferrite
head
for
erasure
41.0cm(W)
x
14.2cm(H)
x
25.4cm(D)
4
5kg
Matsushita
Electric
Trading
Co.,
Ltd.
P.O.
Box
288,
Central
Osaka
Japan
Question and Answer IconNeed help?

Do you have a question about the Technics RS-M7 and is the answer not in the manual?

Technics RS-M7 Specifications

General IconGeneral
Track System4-track, 2-channel stereo
MotorDC Servo Motor
Tape TypeNormal, CrO2, Metal
Wow and Flutter0.05% (WRMS)
Tape Speed4.8 cm/s
Heads1 x record/playback, 1 x erase
Noise ReductionDolby B
Dimensions430 x 130 x 290mm
Output400mV (line)

Summary

Location of Controls and Components

Disassembly Instructions

Measurements and Adjustments

Head Azimuth Adjustment

Procedure for adjusting the record/playback head angle for maximum output.

Tape Speed Accuracy and Fluctuation

Measuring and adjusting tape speed accuracy and fluctuations.

Playback Gain Adjustment

Measuring and adjusting playback gain for both channels.

Bias Current Adjustment

Adjusting the bias current for recording, with conditions and measurement.

Erase Current Measurement

Measuring erase current using a resistor and voltage.

Overall Gain Adjustment

Measuring and adjusting recording/playback gain.

Level Meter Adjustment

Adjusting input levels for the VU meters to indicate 0dB.

Overall Frequency Response Measurement

Measuring frequency response for record/playback across different tape types.

Recording Equalizer Coil Adjustment

Adjusting equalizer coils for normal tape recording response.

Dolby Circuit Adjustment

Checking Dolby circuit performance by comparing signal levels.

Frequency Response Adjustment

Adjusting frequency response using bias current for tape types.

Dolby NR Circuit Operation Check

Confirming Dolby NR circuit gain difference between IN and OUT positions.

Bias Current Measurement for Recording

Measuring bias current using VTVM and formula.

Erase Current Measurement

Measuring erase current by voltage across a 1 Ohm resistor.

Overall Gain Measurement

Measuring overall gain using AF oscillator, VTVM, and test tape.

Level Meter Calibration

Adjusting VR501 and VR502 for level meters to indicate 0dB.

Overall Frequency Response Charts

Charts detailing frequency response tolerances for various tape types.

Overall Frequency Response Adjustment

Adjusting frequency response using bias current.

Adjustment Parts Location

Electrical Parts List

Cabinet Parts List

Schematic Diagram

Wiring Connection Diagram

Exploded Views

Related product manuals