Overall
frequency
response
Equipment:
*
VTVM
*
AF
oscillator
*
ATT
*
Test
tape
(reference
blank
tape)
++
QZZCRA
for
Normal
«+
QZZCRX
for
CrOz
++
QZZCRY
for
FeCr
MEASUREMENT
&
ADJUSTMENT
.
Supply
1kHz
signal
to
LINE
IN
and
adjust
ATT
so
that
output
level
at
LINE
OUT
indicates
0.39
V.
.
Make
recording.
.
Playback
and
measure
distortion
factor
of
output
signal.
.
When
the
distortion
factor
does
not
satisfy
the
standard,
check
the
bias
current.
When
the
bias
current
is
lower
than
standard,
distor-
tion
will
increase.
Care
should
be
exercised
in
the
adjustment
because
the
bias
current
also
has
an
influence
on
the
overall
frequency
response.
Refer
to
“The
overall
frequency
response”
and
“The
bias
current
adjustment”.
Standard
value:
Less
than
3.0%
(Normal
position)
Less
than
4.0%
(CrO2,
FeCr
position)
Note:
Before
measuring,
and
adjusting,
make
sure
of
the
playback
frequency
response
(For
the
method
of
measurement,
please
refer
to
the
playback
frequency
response).
1.
2
SB:
4
Test
equipment
connection
is
shown
in
fig.
18.
.
Load
reference
blank
test
tape
and
place
UNIT
into
record
mode.
Supply
1kHz
signal
from
AF
oscillator
through
ATT
to
LINE
IN.
.
Adjust
ATT
so
that
input
level
is
—20dB
below
standard
recording
evel
(standard
recording
level
24
dB).
.
Record
each
frequency
50Hz,
100Hz,
200Hz,
1kHz,
2kHz,
4kHz,
8kHz
and
10kHz
(12
kHz
for
CrO2
and
FeCr
tape)
at
the
same
level.
.
Playback
and
express
in
dB
the
difference
between
playback
output
level
of
each
frequency
based
on
playback
output
level
of
1kHz.
.
Make
sure
that
the
measured
value
is
within
the
range
specified
in
the
overall
frequency
response
chart.
“Overall
frequency
response
chart
(Normal)
2kHz
:
Fig.
21
.
Set
the
tape
selector
to
CrOz,
FeCr
position.
.
Measure
as
same
as
manner
above.
.
Make
sure
that
the
measured
value
is
within
the
range
specified
in
the
overall
frequency
response
chart
for
CrOz
and
FeCr
tape
below.
Overall
frequency
response
chart
(FeCr)
kHz ake
orate
100Hz
REMARKS
*
Record/playback
mode
*
INPUT
level
control
MAX