HEAD
AZIMUTH
ADJUSTMENT
(DECK
1/2)
1.
Playback
the
azimuth
adjustment
portion
(8kHz,
—20dB)
of
the
test
tape
(QZZCFM).
Vary
the
azimuth
adjusting
screw
until
the
outputs
of
the
L-CH
and
R-CH
are
maximized
and
the
lissajous
waveform,
as
illustrated,
approaches
0
degrees.
Note:
If
L-CH
and
R-CH
are
not
maximized
at
the
same
point,
adjust
to
the
point
where
the
levels
of
each
channel
are
maximized
and
equal.
2.
Perform
the
same
adjustment
in
the
play
mode.
3.
After
the
adjustment,
apply
screwlock
to
the
azimuth
adjusting
screw.
TAPE
SPEED
ADJUSTMENT
(DECK
1/2)
Normal
speed
1.
Shift
the
edit-recording
tape-speed
selector
to
“X1”.
2.
Playback
the
middle
portion
of
the
test
tape
(QZZCWAT).
3.
Adjust
Deck
1=VR902
and
Deck
2=VR903
so
that
the
output
is
within
the
standard
value.
High
speed
4.
Shift
the
edit-recording
tape
speed
switch
to
“X2”.
5.
Playback
the
middle
portion
of
the
test
tape
(QZZCWAT).
6.
Adjust
Deck
1=VR901
so
that
the
output
is
within
the
standard
value.
Note:
The
Normal
speed
adjustment
must
be
done
before
the
High
speed
adjustment.
E.HEAD
R/P.
HEAD
Azimuth
Screw
Azimuth
Screw
Azimuth
Screw
(Forward)
(Reverse)
{DECK
2)
(DECK
1)
Fig.
2
LINE
OUT
Digital
frequency
counter
(DECK
2)Standard
value:
3000
+
15
Hz
[Normal
(X1)],
6000
+
600
Hz
[High
(X2),
only
confirmation]
(DECK
1)Standard
value:
3000
+
15
Hz
[Normal
(X1)],
6000
+
30
Hz
[High
(X2)]
PLAYBACK
GAIN
ADJUSTMENT
(DECK
1/2)
1.
Playback
the
gain
adjusted
portion
(315Hz,
0dB)
of
the
test
tape
(QZZCFM).
2.
Adjust
Deck
1=
VR3
(L-CH)
[[VR4
(R-CH)]]
and
Deck
2
=VR5
(L-CH)
[[VR6
(R-CH)]]
so
that
the
output
is
within
the
standard
value.
Standard
value:
0.4V+0.5dB
PLAYBACK
FREQUENCY
RESPONSE
(DECK
1/2)
1.
Playback
the
frequency
response
portion
(315Hz,
12.5kHz~63Hz,
—20dB)
of
the
test
tape
(QZZCFM).
2.
Assure
that
the
frequency
response
is
within
the
range
shown
in
Fig.
6
for
both
L-CH
and
R-CH.
LINE
OUT
LINE
OUT
4-4
+508
|_|+3B
+208
ae
048
:
;
—20B
4
--+}-|—34B
1
q
:
HE
—54B
T
T
Littl
63Hz
100Hz
200Hz
[s00Hz
1kHz
2kHz2
4kHz
12.5kHz
315Hz
8kHz
Fig.
6
RS-X101
ERASE
CURRENT
ADJUSTMENT
(DECK
2)
1.
Insert
the
Metal blank
test
tape
(QZZCRZ)
and
set
the
unit
to
the
Record
Pause
mode.
2.
Adjust
VR301
so
that
the
output
between
TP3
and
GND
ERASE
HEAD
EVM
is
within
the
standard
value.
.
R301
10
(Electronic
Standard
value:
190+5mA
(Metal)...EVM
Reading:
190+5mV
Fig.
7
Voltmeter)
OVERALL
FREQUENCY
RESPONSE
(DECK
2)
Normal
Overall
frequency
response
chart
(NR
OUT)
1.
Insert
the
Normal
blank
test
tape
(QZZCRA)
and
set
the
unit
to
the
Record
Pause
mode.
2.
Apply
a
reference
input
signal
(1kHz,
—24dB)
through
an
attenuator.
3.
Attenuate
the
signal
by
20dB
and
adjust
the
frequency
from
50Hz~10kHz.
4.
Record
the
frequency
sweep.
5.
Playback
the
recorded
signal
and
assure
that
it
is
within
the
range
shown
in
Fig.
8
in
comparison
to
the
reference
50Hz
100Hz
200Hz
500Hz
1kHz
2kHz
frequency
(1kHz).
6.
If
it
is
not
within
the
standard
range,
adjust
VR303
Fig.
8
(L-CH)
and
VR302
(R-CH)
so
that
the
frequency
level
is
within
the
standard
range.
CrO,
Metal
Overall
frequency
response
chart
(NR
OUT)
¢
Level
up
in
high
frequency
range
Increase
the
bias
current.
¢
Level
down
in
high
frequency
range
...Decrease
the
bias
current.
7.
Repeat
steps
2~6
above
using
the
CrO,
tape
(QZZCRX)
and
the
Metal
tape
(QZZCRZ)
increasing
the
frequency
range
to
12.5kHz
(50Hz~
12.5
kHz).
8.
Assure
that
the
level
is
within
the
range
shown
in
Fig.
9.
+6dB
+4dB
+20B
0dB
—20B
—40B8
—6dB)
H
LINE
IN
LINE
OUT
SOHz
100Hz
200Hz
SOOHz
1kHz
2kHz
EVM
Oscilloscope
Fig.
9
OVERALL
GAIN
ADJUSTMENT
(DECK
2)
.
Insert
the
Normal
blank
test
tape
(QZZCRA)
and
set
the
unit
to
the
Record
pause mode.
-
Apply
a
_
reference
input
signal
(1kHz,
-—24dB).
Attenuate
the
output
so
that
its
level
becomes
0.4V.
.
Record
this
input
signal.
LINE
IN
LINE
OUT
.
Playback
the
signal
recorded
in
step
3
above,
and
assure
that
the
output
is
within
the
standard
value.
.
If
it
is
not
within
the
standard
value,
adjust
VR7
(L-CH)
and
VR8
(R-CH).
.
Repeat
the
step
2~5
above
until
the
output
is
within
the
standard
value.
Standard
value:
0.4V+0.5dB
EVM
Oscitloscooe

Related product manuals