89
ON / OFF Start function ON/OFF (ex works
1
= ex works
2
= OFF)
COLL Setting of collector sensor (ex works
1
= S1, ex works
2
= S2).
Setting range:
S1 to S6
GBS Radiation sensor GBS 01 - non-standard accessory: Indicates a sensor input if
a radiation sensor is used. If no radiation sensor is used, the average
temperature (long-term mean regardless of the weather) is calculated. (ex
works
1
= ex works
2
= --)
Setting range: S1 to S6 Input of radiation sensor
E1 to E9 Value of the external sensor
GBS -- = no radiation sensor
RTH Radiation value (radiation threshold) in W/m
2
above which rinsing is allowed.
Without a radiation sensor, the computer calculates the necessary temperature
increase for the long-term mean that launches rinsing from this value. (ex
works
1
= ex works
2
= 150W/m
2
)
Setting range: 0 to 990W/m
2
in increments of 10W/m
2
OP
Outputs to be monitored. If one of the outputs set is running, no start function
needs to be executed. (ex works
1
= OP1, ex works
2
= OP2)
Setting range: combination of all outputs (such as OP1, OP23, OP123)
OPS Outputs used for rinsing. If a control output is allocated to the output, then the
analog stage 100 is additionally output at this control output.
(ex works
1
= OPS1, ex works
2
= OPS2)
Setting range: combination of all outputs (such as OPS1, OPS23, OPS123)
PRT Pump run-time (rinsing time) in seconds. During this time, the pump(s) should
have pumped roughly half of the content of the collector’s heat transfer medium
past the collector sensor. (ex works
1
= ex works
2
= 15s)
Setting range: 0 to 240 seconds in increments of 1 sec
INT(max) Maximum allowable interval between two rinses. This time is automatically
reduced according to the temperature increase after rinsing. (ex works
1
= ex
works
2
= 20min)
Setting range: 0 to 99 minutes in increments of 1 min
NSA Number of start attempts (= counter). The system is automatically reset for a
start attempt if the last start attempt was more than four hours ago.
Priority PRIOR
This menu item is only displayed for program diagrams with priority.
When the consumers with lower priority are being filled, the unit monitors the irradiation
at the radiation sensor or the collector temperature. If a radiation threshold is reached or the
collector temperature is exceeded by a value calculated from the threshold for the low-priority
consumer, the priority timer is activated. The pump then switches off for a set waiting time of
60 sec.

Table of Contents

Other manuals for Technische Alternative UVR61-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technische Alternative UVR61-3 and is the answer not in the manual?

Technische Alternative UVR61-3 Specifications

General IconGeneral
BrandTechnische Alternative
ModelUVR61-3
CategoryDryer
LanguageEnglish