8. Remedial maintenance: Error detection.
8.1.Malfunctions
1st level troubleshooting
- The control unit screen does
not work.
- The control unit is not getting
any power.
- The screen or ribbon cable
does not work.
- Check the condition and
connection of the power cord.
- Check the position of the on/off
switch.
- Contact the After-Sales Customer
Service Team.
- The marking depth is not
sufficient and/or constant.
- The stylus is worn and/or
chipped.
- The stylus is dirty and/or partly
stuck in the guide.
- The spring is worn.
- The distance between the
stylus and the part is almost
10mm and the ripples on the
part mean that the stylus is
sometimes blocked.
Sharpen or replace the stylus.
Clean and lubricate the stylus.
Change the stylus return spring.
Move the machine closer to the part
to be marked.
- There is not impact during
marking.
- A test is carried out rather
than the start of a cycle.
- The stylus is stuck and/or does
not return to its original
position, is not lowered.
Check the control of the machine by
the master device.
Clean the stylus, check the condition
of the return spring and the
presence of the core. Tighten the
knurled nut manually.