EasyManua.ls Logo

Technomark M4 inline - User Manual

Technomark M4 inline
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page1sur47
TRAÇABILITÉCRÉATIVE
CREATIVETRACEABILITY
www.technomark-marking.com
Modèle du 29/10/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : info@technomark-marking.com
SoftwareUserGuide
Type Originalrevision20/08/2014
Revision 1.1‐b
Date 09/11/2015
Writtenby DD
Controlledby SJ
3AlléeMichaëlFARADAY
Parcd’ActivitésSTELYTEC
42400SAINT‐CHAMOND
FRANCE
www.technomark‐marking.com
Tél.:+33(0)477222591
Fax:+33(0)477223891

Table of Contents

Other manuals for Technomark M4 inline

Questions and Answers

  • D
    David AndrewsSep 23, 2025
    What to do if Technomark Label Maker displays error code 59?
    • M
      Molly JohnsonSep 23, 2025
      If the Technomark Label Maker displays error code 59, related to a 16-channel line error, check the configuration of the 16 channels.
  • S
    Susan KimAug 25, 2025
    What to do if Technomark M4 inline Label Maker displays error code 13?
    • C
      Crystal AlvarezAug 25, 2025
      If the Technomark Label Maker shows error code 13, it means there's no marking head detected. Ensure the head is correctly connected and the connector is locked, then restart the controller. Inspect the cable's condition. Also, check for any obstructions blocking the striker unit's path and restart the controller. If needed, power off the device and manually check if the machine can move to its original position freely.
  • D
    dwaynetravisAug 25, 2025
    What to do if Technomark M4 inline displays error code 9?
    • W
      walkerkennethAug 26, 2025
      If the Technomark Label Maker displays error code 9, it signifies an open circuit. You should check the condition of the striker unit cable, ensuring it is not cut or damaged, and then restart the controller. Also, inspect the striker unit connector to confirm it is undamaged and properly connected before restarting the controller. Additionally, verify the condition of the marking head cable and restart the controller.
  • K
    Kaylee WardAug 27, 2025
    What to do if Technomark M4 inline Label Maker displays error code 10?
    • K
      kyle95Aug 27, 2025
      If the Technomark Label Maker displays error code 10, which indicates a weak current, check the condition of the striker unit cable and restart the controller. Also, inspect the striker unit connector, ensuring it's properly connected, and then restart the controller.
  • R
    Rebecca WarnerAug 27, 2025
    What to do if Technomark Label Maker shows error codes 43, 44, 45, 46?
    • O
      oknoxAug 27, 2025
      If the Technomark Label Maker gives error codes 43, 44, 45, or 46 related to USB stick errors, try using a different USB stick. If that doesn't work, restart the controller.
  • S
    Shelley RobertsSep 16, 2025
    What to do if Technomark Label Maker displays error code 51?
    • T
      Tammy PatrickSep 16, 2025
      If the Technomark Label Maker displays error code 51, indicating that it's marking busy, wait for the current task to finish or stop it.
  • D
    davidhunterSep 13, 2025
    How to fix matrix error on Technomark M4 inline?
    • J
      Jamie TuckerSep 13, 2025
      If the Technomark Label Maker displays error code 4, a matrix error, change the matrix of the text.
  • N
    Nathan GonzalezSep 14, 2025
    What to do if Technomark M4 inline displays error code 49?
    • A
      Amy SilvaSep 15, 2025
      If the Technomark Label Maker shows error code 49, a window error, check the marking overview for any flags indicating marking outside of the window and reposition the text.
  • W
    woodjosephSep 5, 2025
    What to do if Technomark M4 inline displays error code 12?
    • C
      Christina FreySep 5, 2025
      If the Technomark Label Maker shows error code 12, which indicates an abandonment error, it means the current marking operation was interrupted. Restart the marking process and check at which point it was interrupted.
  • T
    timothy94Sep 3, 2025
    What to do if Technomark M4 inline Label Maker displays error 50?
    • M
      mccarthyjamesSep 3, 2025
      If the Technomark Label Maker shows error code 50, a temperature error, turn the controller off for about ten minutes, then restart it. If the issue persists, try reducing the number of impacts by using a different font, reducing the marking speed, or reducing the marking force.

Summary

Introduction

Manuals

Main Screen and General Operation

Front Panel Components

Overview of the M4 inline front panel buttons, screen, and ports.

Toolbar Functionality

16 Channels State Display

Dashboard Indicators

Graphic View Mode

View Mode Options

Explains different graphic view modes like Normal, 30x30 zoom, Total, and Text.

File Edition

File Edition Toolbar Features

Details on toolbar buttons for inserting marking/mechanical functions, file configuration, and special characters.

Marking File Columns

Explanation of columns used in the marking file data table, including text, position, and height.

Text Formatting Options

Description of text formatting options such as compression, character spacing, and italic inclination.

Marking Depth and IDI Function

Details on how marking depth is influenced by force and distance, and the IDI function.

Dot Matrix Selection

Overview of available dot matrix types and their impact on the duty cycle.

Adding Marking Functions

Guide to adding various marking functions like serial numbers, variables, timestamps, logos, and codes.

Serial Number Configuration

Instructions for configuring serial numbers, including name, value, step, frequency, and zero marking.

Variable Configuration

Steps for creating and using variables, including types like VSHARED and bar code variables.

Timestamp Configuration

How to configure timestamps using date, hour, and team name codes.

Logo Insertion

Procedure for inserting logos created with TechnoLOG software into marking files.

2 D Code (Datamatrix;QR) Configuration

Configuration details for adding Datamatrix and QR codes, including text, speed, and format.

Mechanical Function Setup

Options for adding mechanical functions like pause, crossing point, inputs, outputs, and ZInline moves.

Pause Functionality

How to set a pause status within a marking line.

Crossing Point Definition

Procedure to force the marking head to pass through a defined point.

Waiting Input Configuration

Configuration for waiting a specific state of an input, with delay and state options.

Output Change Configuration

How to change an output state using a file line, including number, delay, and state.

ZInline Axis Moves

Instructions for ZInline moves: to Home, to Mark, and relative moves.

General Marking Settings

Configuration of general marking parameters including speed, IDI, mirroring, and stylus height.

Special Character Addition

Information on adding special characters, currently unavailable.

Positioning and Testing Operations

Procedures for moving the marking head, testing line/file envelopes, and performing marking tests.

File Operations

Saving and Opening Files

Instructions for saving the current file and opening existing marking files.

Creating and Importing Files

Steps for creating new files and importing marking files from a USB drive.

Exporting Files

Procedure for exporting marking files and logos from the controller to a USB drive.

Maintenance

Information Display

Display of controller information including file system, statistics, software release, and hardware details.

Maintenance Procedures

Overview of maintenance tasks and requirements, including lubrication and axis revisions.

IDI Track and Mechanical Surveillance

Enabling IDI track function and controlling mechanical surveillance for stylus, part presence, and lubrication.

Auto Diagnosis and Debug Mode

Using auto diagnosis for mechanical checks and debug mode for system monitoring.

Error Log and Output Control

Viewing the error log and controlling output states, including ZInline axis moves.

IDI Calibration Procedure

Step-by-step procedure for calibrating the IDI function for accurate marking.

Settings

General Settings Configuration

Setting general parameters for the control box, including language, units, autosave, and screen brightness.

Date and Time Configuration

Configuring the controller's date, time, time zone, and team information.

Custom Timestamp Formatting

Defining custom formats for timestamps using day, month, year, and team data.

Mechanical Settings

Configuring mechanical settings such as window size, bidirectionnal mode, and optimized speed.

16-Way Input;Output Settings

Detailed configuration of the 16-way input/output ports and their associated functions.

Input;Output Function Details

Explanation of specific input functions like File Open and output functions like Ready, Marking, and Fault.

Communication Settings

Configuring serial communication parameters and TCP/IP settings for network connectivity.

User Management

Managing user accounts, privileges, and password settings for machine access.

Function Lock and Password

Locking machine functionalities and changing the supervisor password.

License Management

Instructions for entering license numbers to activate software features.

Origin Management Settings

Configuring origin set modes for startup and marking, and defining parking points.

Technomark M4 inline Specifications

General IconGeneral
BrandTechnomark
ModelM4 inline
CategoryLabel Maker
LanguageEnglish