What to do if the TECNA Industrial Equipment breaker operates with reduced power?
- MmarshallzoeAug 11, 2025
If your TECNA Industrial Equipment breaker operates with reduced power, several factors could be the cause. First, the pressure in the hydraulic system might be too low, requiring you to check the hydraulic system on the support frame and increase the pressure. High hydraulic oil temperature can also cause this issue. Another potential cause is leakage in the hydraulic system, which would need to be checked and repaired. Additionally, a defect in the accumulator, indicated by strongly vibrating pressure hoses, may require removing or replacing the diaphragm by an authorized service. Finally, a low oil flow rate could be the culprit, necessitating an increase in the oil flow rate.