EasyManua.ls Logo

Tecnoalarm Evolution EV 10-50 - Page 22

Tecnoalarm Evolution EV 10-50
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EV 10-50
22
Wireless hybrid  arm sy em
Wireless hybrid  arm sy em
Partial disarming of the programs armed
The procedure allows you to partially disarm the activated programs, partial disarming can only be performed by the keys enabled for this function.
The procedure is carried out in two stages
1 Turn on the reader
Press the button
2 Partially disarm the programs Move the key enabled to perform partial disarming of programs close to the reading area
Program arming with exclusion of open zones
The procedure allows you to arm a program excluding open zones, after selecting the program to be armed, the OCG LED ashes indicating the
presence of open zones. The procedure is carried out in three stages
1 Turn on the reader
Press the button
2 Select the program Move the key up to and away from the reading area, one or more times, until the desired program is selected
3 Exclude open zones Move the key up to the reading area, the OCG LED turns off and the program is armed excluding the open zones
The program and OCG
LEDs ash
Program
status
LED
Operations
At the end of the Time-out
the reader turns off
The program LED
ashes fast
Program selected
Program armed with open
Zones excluded
Program arming
Program LEDs off
Programs disarmed
Press the button
Move the key close and wait for
the OCG LED to switch off
Move the key close, one or more times,
until the desired program is selected
The program LEDs
ash slowly
Program
status
LED
Operations
Programs partset
Partial disarming in
progress
Program LEDs on
Programs armed
Press the button Move the key close
At the end of the Time-out
the reader turns off