EasyManua.ls Logo

TECO A510s Series - Page 42

TECO A510s Series
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Group 14: PLC Setting Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
14-37
MD1 Set Value 2
0~65534 (Note4)
1 Note6
14-38
MD1 Set Value 3
0~65534 (Note4)
1 Note6
14-39
MD2 Set Value 1
0~65534 (Note4)
1 Note6
14-40
MD2 Set Value 2
0~65534 (Note4)
1 Note6
14-41
MD2 Set Value 3
0~65534 (Note4)
1 Note6
14-42
MD3 Set Value 1
0~65534 (Note4)
1 Note6
14-43
MD3 Set Value 2
0~65534 (Note4)
1 Note6
14-44
MD3 Set Value 3
0~65534 (Note4)
1 Note6
14-45
MD4 Set Value 1
0~65534 (Note4)
1 Note6
14-46
MD4 Set Value 2
0~65534 (Note4)
1 Note6
14-47
MD4 Set Value 3
0~65534 (Note4)
1 Note6
Group 15: PLC Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
15-00
T1 Current Value1
0~9999 0
15-01
T1 Current Value 2
(Mode7)
0~9999 0
15-02
T2 Current Value 1
0~9999 0
15-03
T2 Current Value 2
(Mode7)
0~9999 0
15-04
T3 Current Value 1
0~9999 0
15-05
T3 Current Value 2
(Mode7)
0~9999 0
15-06
T4 Current Value 1
0~9999 0
15-07
T4 Current Value 2
(Mode7)
0~9999 0
15-08
T5 Current Value 1
0~9999 0
15-09
T5 Current Value 2
(Mode7)
0~9999 0
15-10
T6 Current Value 1
0~9999 0
15-11
T6 Current Value 2
(Mode7)
0~9999 0
15-12
T7 Current Value 1
0~9999 0
15-13
T7 Current Value 2
(Mode7)
0~9999 0
15-14
T8 Current Value 1
0~9999 0
15-15
T8 Current Value 2
(Mode7)
0~9999 0
15-16
C1 Current Value
0~65534 (Note4)
0
15-17
C2 Current Value
0~65534 (Note4)
0
15-18
C3 Current Value
0~65534 (Note4)
0
15-19
C4 Current Value
0~65534 (Note4)
0
15-20
C5 Current Value
0~65534 (Note4)
0
15-21
C6 Current Value
0~65534 (Note4)
0
15-22
C7 Current Value
0~65534 (Note4)
0
15-23
C8 Current Value
0~65534 (Note4)
0
15-24
AS1 Current Value
0~65534 (Note4)
0
15-25
AS2 Current Value
0~65534 (Note4)
0
15-26
AS3 Current Value
0~65534 (Note4)
0
15-27
AS4 Current Value
0~65534 (Note4)
0
15-28
MD1 Current
Value
0~65534 (Note4)
0
15-29
MD2 Current
Value
0~65534 (Note4)
0
15-30
MD3 Current
0~65534 (Note4)
0
Group 15: PLC Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Value
15-31
MD4 Current
Value
0~65534 (Note4)
0
15-32
TD Current Value
0~65534 (Note4)
0
Group 16: LCD Function Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
16-00
Main Screen
Monitoring
5~82
(Note4)
when using
LCD to
operate, the
monitored item
displays in the
first line.
(default is
frequency
command)
16 *1
16-01
Sub-Screen
Monitoring 1
5~82
(Note4)
when using
LCD to
operate, the
monitored item
displays in the
second line.
(default is
output
frequency)
17 *1
16-02
Sub-Screen
Monitoring 2
5~82
(Note4)
when using
LCD to
operate, the
monitored item
displays in the
third line.
(default is
output current)
18 *1
16-03 Display Unit
0~39999
Determine the
display way
and unit of
frequency
command
0
0: Frequency
display unit is
0.01Hz
1: Frequency
display unit is
0.01%
2: Frequency
display unit is
rpm.
3~39:

Other manuals for TECO A510s Series