42
Group 16: LCD Function Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Reserved
40~9999:
Users specify
the format,
Input 0XXXX
represents the
display of
XXXX at 100%.
10001~19999:
Users specify
the format;
Input 1XXXX
represents the
display of
XXX.X at
100%.
20001~29999:
Users specify
the format,
Input 2XXXX
represents the
display of
XX.XX at
100%.
30001~39999:
Users specify
the format,
Input 3XXXX
represents the
display of
X.XXX at
100%.
16-04
Engineering
Unit
0: without
using
engineering
unit
0
1: FPM
2: CFM
3: PSI
4: GPH
5: GPM
6: IN
7: FT
8: /s
9: /m
10: /h
11: °F
12: inW
13: HP
14: m/s
15: MPM
16: CMM
17: W
18: KW
19: m
20: °C
21: RPM
22: Bar
Group 16: LCD Function Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
23: Pa
24: KPa
16-05 LCD Backlight 0~7 5 *1
16-06 Reserved
16-07
Copy Function
Selection
0: Do not copy
parameters
0
1: Read
inverter
parameters and
save to the
operator.
2: Write the
operator
parameters to
inverter.
3: Compare
parameters of
inverter and
operator.
16-08
Selection of
Allowing
Reading
0: Do not allow
to read inverter
parameters and
save to the
operator.
0
1: Allow to read
inverter
parameters and
save to the
operator.
16-09
Selection of
Operator
Removed
(LCD)
0: Keep
operating
when LCD
operator is
removed.
0 *1
1: Display fault
when LCD
operator is
removed
16-10
RTC Time
Display Setting
0: Hide
0 Note8
1: Display
16-11
RTC Date
Setting
12.01.01 ~
99.12.31
12.01.0
1
Note8
16-12
RTC Time
Setting
00:00 ~ 23:59 00:00 Note8
16-13
RTC Timer
Function
0: Disable
1: Enable
2: Set by DI
0 Note8
16-14 P1 Start Time 00:00 ~ 23:59 08:00 Note8
16-15 P1 Stop Time 00:00 ~ 23:59 18:00 Note8
16-16 P1 Start Date
1:Mon
2:Tue
3:Wed
4:Thu
5:Fri
6:Sat
7:Sun
1 Note8
16-17 P1 Stop Date 5 Note8
16-18 P2 Start Time
00:00 ~ 23:59
08:00 Note8
16-19 P2 Stop Time
00:00 ~ 23:59
18:00 Note8