4-25
Group 01: V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
01-24
Base Frequency
of Motor 2
4.8~599.0
50.0/
60.0
Hz O X X X X X X *8
01-25
Base Output
Voltage of
Motor 2
200V: 0.0~255.0 -
V O X X X X X X *8
400V: 0.0~510.0 -
575V: 0.0~670.0 -
690V: 0.0~804.0 -
01-26
V/F Curve
Selection of
Motor 2
0~FF F - O X X X X X X *3
KVA: The default value of this parameter will be changed by different capacities of inverter.
Group 02: IM Motor Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
02-00
No-Load Current
of Motor1
0.01~600.00 - A O X X X X X O
02-01
Rated Current of
Motor1
Modes of V/F, V/F+PG
are 10%~200% of
inverter’s rated current.
Modes of SLV, SV are
25%~200% of inverter’s
rated current.
- A O O O O X X O
02-02 Reserved
02-03
Rated Rotation
Speed of Motor1
0~60000 - Rpm O O O O X X O
02-04
Rated Voltage of
Motor1
200V: 50.0~240.0 -
V O O O O X X O *8
400V: 100.0~480.0 -
575V: 150.0~670.0 -
690V: 200.0~804.0 -
02-05
Rated Power of
Motor1
0.01~600.00 - kW O O O O X X O
02-06
Rated Frequency
of Motor1
4.8~599.0
50.0/
60.0
Hz O O O O X X O *8
02-07 Poles of Motor 1 2~16(Even) 4 - O O O O X X O
02-08 Reserved
02-09
Excitation Current
of Motor 1
15%~70% of Motor
Rated Current
- % X X O O X X X
02-10
Core Saturation
Coefficient 1
of Motor 1
1~100 - % X X O O X X X