4-24
Group 01: V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
01-11
Selection of
Torque
Compensation
Mode
0: Torque Compensation
Mode 0
0 - O O X X X X X
1: Torque Compensation
Mode 1
01-12
Base Frequency
of Motor 1
4.8~599.0
50.0/
60.0
Hz O O O O O O O *8
01-13
Base Output
Voltage of
Motor 1
200V: 0.0~255.0 -
V O O X X X X O *8
400V: 0.0~510.0 -
575V: 0.0~670.0 -
690V: 0.0~804.0 -
01-14
Input Voltage
Setting
200V: 155.0~255.0 -
V O O O O O O O *8
400V: 310.0~510.0 -
575V: 540.0~670.0 -
690V: 648.0~804.0 -
01-15
Torque
Compensation
Time
0~10000 200 ms O O X X X X O
01-16
Maximum Output
Frequency of
Motor 2
4.8~599.0
50.0/
60.0
Hz O X X X X X X *8
01-17
Maximum Output
Voltage of Motor
2
200V: 0.1~255.0 -
V O X X X X X X *8
400V: 0.2~510.0 -
575V: 0.1~670.0 -
690V: 0.1~804.0 -
01-18
Middle Output
Frequency 2 of
Motor 2
0.0~599.0 0.0 Hz O X X X X X X
01-19
Middle Output
Voltage 2 of
Motor 2
200V: 0.0~255.0
0.0 V O X X X X X X
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0
01-20
Middle Output
Frequency 1 of
Motor 2
0.0~599.0 3.0 Hz O X X X X X X
01-21
Middle Output
Voltage 1 of
Motor 2
200V: 0.0~255.0
KVA V O X X X X X X
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0
01-22
Minimum Output
Frequency of
Motor 2
0.0~599.0 1.5 Hz O X X X X X X
01-23
Minimum Output
Voltage of Motor
2
200V: 0.0~255.0
KVA V O X X X X X X
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0