Apply power to the drive, the display will briefly show the supply voltage
440V followed by flashing.
This is the default (factory set) frequency.
If the unit has been used previously then it will show the last frequency
programmed.
Step 2
Apply power to the drive
Step 3
Test run from keypad
Press RUN KEY to run.
The frequency will ramp up to 5.0 Hz or the user pre-set frequency
according to the default acceleration ramp time.
Press STOP key to stop.
The frequency will ramp down to zero according to the default decel ramp
time.
Step 4
To alter frequency from keypad. (Default setting).
Use the Arrow keys and
</
RESET key
to alter the digits to the
required frequency.
To store the set frequency use READ/ENTER Key.
eg. 50.0 HZ then use RUN and STOP keys to start/ stop.