46
Address
Parameter
Name & Function Default
Unit
Setting
Range
RS232
RS485
Speed command smooth accel/decel time Constant.
Sn206
Set Sn205=1
to enable this function then set the time period for
the speed to rise to 63.2% of the full speed.
1 msec
1
10000
52BH
0206H
Speed command linear accel/decel time constant.
Sn207
Set Sn205=2
to enable this function then set the time period for
the speed to rise linearly to full speed.
100
50
Ratio Speed
Speed Command
(%)
Speed Command
Sn207
Time (ms)
1 msec
1
50000
52CH
0207H