Group 07- Start/Stop command setup
No. Description Range
Factory
Setting
Note
Level at
Start
07-11
DC Braking
T
ime at Star
t
0.0~25.5 0.0
Group 08- Drive & Motor Protection
functions
No. Description Range
Factory
Setting
Note
08-00
T
rip
Prevention
Selection
x
xxx0: Enable Trip
Prevention During
A
cceleration
x
xxx1: Disable Trip
Prevention During
A
cceleration
x
xx0x: Enable Trip
Prevention During
Deceleration
x
xx1x: Disable Trip
Prevention During
Deceleration
x
x0xx: Enable Trip
Prevention in Run
Mode
x
x1xx: Disable Trip
Prevention in Run
Mode
x
0xxx: Enable over
v
oltage Prevention
in Run Mode
x
1xxx: Disable
o
ver voltage
Prevention
in Run Mode
00000
08-01
T
rip
Prevention
Level
During
A
cceleration
(%)
50 ~ 200 by series
08-02
T
rip
Prevention
Level
During
Deceleration
(%)
50 ~ 200 by series
08-03
T
rip
Prevention
Level In
Run Mode
(%)
50 ~ 200 by series
08-04
o
ver voltage
Prevention
Level in Run
Mode
2
00V: 350.0~390.0
4
00V: 700.0~780.0
380.0/76
0.0
*1
08-05
Electronic
Motor
Overload
x
xxx0: Disable
Electronic Motor
Overload
00001
Group 08- Drive & Motor Protection
functions
No. Description Range
Factory
Setting
Note
Protection
Operation
Mode
Protection
x
xxx1: Enable
Electronic Motor
Overload
Protection
x
xx0x: Motor
Overload Cold
Start
x
xx1x: Motor
Overload Hot Start
x
x0xx: Standard
Motor
x
x1xx: Invertor
Duty Motor ( Force
V
ent)
08-06
Operation
A
fter
Overload
Protection is
A
ctivated
0: Coast-to-Stop
A
fter Overload
Protection is
A
ctivated
1: Drive Will Not
T
rip when
Overload
Protection is
A
ctivated (OL1)
0
08-07
Over heat
Protection
(cooling fan
control)
0: Auto (Depends
o
n temp.)
1: Operate while in
RUN mode
2
: Always Run
3: Disabled
1
08-08
A
VR
Function
(Auto
V
oltage
Regulation)
0: AVR function
enable
4
1: AVR function
Disable
2
: AVR function
d
isable for stop
3: AVR function
d
isable for
d
eceleration
4
: AVR function
d
isable for stop
and deceleration.
5: When
V
DC>(360V/740V)
, AVR function
d
isable for stop
and deceleration.
08-09
Input phase
lost
protection
0: Disabled
1: Enabled
0
08-10
PTC
Overheat
Function
0: Disable 0
1: Decelerate to
s
top
2
: Coast to stop
3: Continue
running, when
w
arning level is
reached.
Coast to stop,