Chapter 5 Relay Ladder Logic Programming        131 
-  
 
Data register screen on HMI display DR preset value in stop mode and display DR current value in run mode. 
STOP  RUN (DR01 = C01 current value)
 
DR65~DRF0 can retain the current value when SG2 is stopped or powered down.   
The last 40 DR registers that from DRC9 to DRF0 are special data register as shown below.   
DRD0 ~ DRE3 as special registers used to set parameters, the output value function is as follows: 
No.  Function description 
DRD0 AQ01 output mode 
DRD1 AQ02 output mode 
DRD2 AQ03 output mode 
DRD3 AQ04 output mode 
0, voltage mode and reset value when stop; 
1, current mode and reset value when stop; 
2, voltage mode and keep value when stop; 
3, current mode and keep value when stop; 
DRD4 AQ01 output value  
DRD5 AQ02 output value  
DRD6 AQ03 output value  
DRD7 AQ04 output value  
Analog output value 0~4095; 
DRD8  I/O interface hidden  Refer to “Chapter3:LCD Display and Keypad > Original screen” 
DRD9~DRE3 Reserved; 
 
DRC9~DRCF and DRE4~DRF0 as special registers used to store status, the output current value function is as follows: 
No.  Function description 
DRC9  Output pulse number of instruction PLSY 
DRCA  AT01 current degree Fahrenheit 
DRCB  AT02 current degree Fahrenheit 
DRCC  AT03 current degree Fahrenheit 
DRCD  AT04 current degree Fahrenheit 
Used as normal registers when no AT01~AT04 
input, such as don’t connected with extension 
module 4PT; 
DRCE Reserved  
DRCF Reserved  
DRE4  A05 input electric current 0~2000
DRE5  A06 input electric current 0~2000
DRE6  A07 input electric current 0~2000
DRE7  A08 input electric current 0~2000
Used as normal registers when no A05~A08 analog 
input, such as don’t connected with extension 
module 4AI; 
DRE8  A01 current value 0~4095 
DRE9  A02 current value 0~4095 
Used as normal registers when no A01 and A02 
analog input, such as AC type; 
DREA  A03 current value 0~4095 
DREB  A04 current value 0~4095 
Used as normal registers when no A03 and A04 
analog input, such as AC type or 12points DC type; 
DREC  A05 current value 0~4095 
DRED  A06 current value 0~4095 
DREE  A07 current value 0~4095 
DREF  A08 current value 0~4095 
Used as normal registers when no A05~A08 analog 
input, such as don’t connected with extension 
module 4AI. 
DRF0 Reserved  
 