4KA72X023 IV
Summary of changes
This user manual is modified by firmware V3.0 and
SG2 Client programming software V3.0. SG2 V3.0 adds some
new functions with firmware version V3.0 to strong SG2 function. The upgrade content is shown as the 2 tables
below simply. More information about idiographic function to see function instruction.
Edit and Display
SG2 V3.0 SG2 V2.x
Ladder 300 lines 200 lines
FBD 260blocks 99blocks
LCD 4 lines * 16 characters 4 lines * 12 characters
Contact and function block
input output SG2 V3.0 SG2 V2.x
Auxiliary relay M M M 63(M01~M3F) 15(M1~MF)
Auxiliary relay N N N 63(N01~N3F) Ladder: NO
FBD: 15(N1~NF)
temperature input AT 4(AT01~AT04) NO
analog output AQ 4(AQ01~AQ04) NO
PWM P 2(P01~P02, P01 adds PLSY mode) 1(P1: PWM)
HMI 31(H01~H1F) 15(H1~HF)
Timer T T Ladder: 31(T01~T1F)
FBD: 250(T01~TFA)
15(T1~TF)
Counter C C Ladder: 31(C01~C1F)
FBD: 250(C01~CFA)
15(C1~CF)
RTC R R Ladder: 31(R01~R1F)
FBD: 250(R01~RFA)
15(R1~RF)
Analog Comparator G G Ladder: 31(G01~G1F)
FBD: 250(G01~GFA)
15(G1~GF)
AS(Add-Sub) Ladder: 31(AS01~AS1F)
FBD: 250(AS01~ASFA)
NO
MD(Mul-Div) Ladder: 31(MD01~MD1F)
FBD: 250(MD01~MDFA)
NO
PID Ladder: 15(PI01~PI0F)
FBD: 30(PI01~PI1E)
NO
MX(Multiplexer) Ladder: 15(MX01~MX0F)
FBD: 250(MX01~MXFA)
NO
AR(Analog Ramp) Ladder: 15(AR01~AR0F)
FBD: 30(AR01~AR1E)
NO
DR(Data Register) 240(DR01~DRF0) NO
MU(MODBUS)
NO NO
Ladder: 15(MU01~MU0F)
FBD: 250(MU01~MUFA)
NO
Logic function: BOOLEAN NO Block
B B
260(B001~B260)The capability o
99(B01~B99)The capability of each
block is fixed
each block is alterable, and the total
capability of block is 6000bytes
PM05(3rd) PM05(3rd) can be used with all
version of SG2
PM05 can not be used with SG2 V3.x