29
Function
Fn_
xx
Description Set Unit Range
Factory
Setting
Page
Parameter
Control for
Communication
102
xxx0 : 1 stop bit xxx1 : 2 stop bits
xx0x : Even parity xx1x : Odd parity
x0xx : With parity x1xx : Without parity
0xxx : 8 bits data 1xxx : 7 bits data
1100
*2 *3
57
103~
122
For factory setting only
*3
Return to Factory
Setting
123 1111: Reset to factory setting (for 60 Hz power system)
1110: Reset to factory setting (for 50Hz power system).
0000
*4
59
CPU version 124 CPU Software Version *3 59
Fault Log 125 Fault Log for last three faults
1. ---
2. ---
3. ---
59
Note: *1: Setting can be changed during run mode.
*2: Setting cannot be changed in communication mode.
*3: Setting will not change with “Reset to factory setting” function.
*4: Refer to function description of Fn_123.
( ): The factory setting of 15~30Hp only.
.
SETTING THE RANGE:
The setting of the Accel. & Decel. Times along with the frequency are only 4 digits when set by the
keypad (for example: 3599 sec / 399.9 Hz),
But 5 digits (for example: 3599.9 sec or 399.99 Hz) are available when controlled by a programmable
controller (PLC) or computer communication mode.