GETTING STARTED continued
The included AC Adaptor/Charger may be Once charging is finished, 'CHARGE' will
used to charge 3 Ni-MH rechargeable stop flashing and the charging indication
batteries (included) when installed onto bars in the upper left corner will stay full.
the PL-450's battery compartment. Before
Charging time varies depending on the
charging, the PL-450 must be set up for
milliamp-hour rating of the batteries. The
use with Ni-MH batteries and the correct
charging circuit automatically senses the
charging rate must be selected for them
milliamp-hour rating of the batteries and
to be charged. Ni-MH batteries are
will charge them for the correct amount of
manufactured with specific capacities
time. Charging time can take from 5.5
rated in milliamp-hours (mAh). These
hours for 1000 mAh batteries to 13 hours
capacities vary from about 1000 mAh up
for 2300 mAh batteries. The charging
to 2400 mAh at the time of this writing
circuit will sense when the batteries are
(usually printed on the batteries). For
fully charged and automatically go into
proper charging without damage to the
trickle-charge mode, thus safeguarding
batteries, the correct charging rate must
the batteries from being overcharged.
be set. To set the charging rate, plug in
Disconnecting the adaptor/charger DC-06
the AC adaptor and turn the PL-450 off.
from the PL-450 or pressing the
Then follow the instructions below.
CHARGE ON/OFF button will also stop
1. Enter SYSTEM SET CODE 28. See charging.
instructions in the section titled
SYSTEM SET CODES.
2. While '1000' flashes in the display, use
the UP /DOWN buttons to select the
mAh rating of your Ni-MH batteries.
To charge Ni-MH batteries:
1. Install 3 Ni-MH AA batteries.
2. Connect the adaptor/charger to the AC
wall.
3. Press/release the CHARGE ON/OFF
button. 'CHARGE' will flash in the
display and the charge indication bars
will advance from bottom to top in the
upper left corner of the display. The
digits in the upper right corner of the
display will change to 00:00 and will
count up in minutes and hours until
charging is finished.