G
CONTINUOUS DRAINAGE
Switch off the unit and remove the plug from the mains.
Place a pan or appropriate tray on the floor underneath the permanent drain
tube to collect any water draining away.
Remove the rubber plug 8.
Connect a drain tube (ø 15 mm) into the water outlet and extend with extra
water tube as needed.
Place the other end of the drain tube at a location suitable for the purpose (a
drain hole, for instance). In doing so, take care to ensure that the tube is not
twisted and is free of kinks. The tube must be placed so as to be declining
along its entire length.
DEHUMIDIFICATION
If the unit will be used mainly as dehumidifier, do not connect the exhaust hose
and let the warm air re t u r n in the room. Continuous drainage is then necessary
and more efficient. You must, however, use a water drain tube (ø 0.5 inch internal
diameter), placing its discharge end at a suitable drainage point.
H
C L E A N I N G
Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol,
d e t e r gents or other cleansing solutions. Clean the screenfilter regularly with a
vacuum cleaner. See also chapter D “Air filter”.
N O T E !
Never use the air conditioner without screenfilter.
WA R N I N G !
First of all switch off the unit and pull the plug.
N O T E !
When the air conditioner is in use, under normal circumstances the
condensed water will be drained through the air outlet-tube.
4
60