Copyright © Teison Energy Technology Co.,Ltd. All Rights Reserved. 31 | P a g e
Solar Mode:
To use the Solar mode, you need to install the CT Meter and connect it to the
same Wi-Fi network as the EV charger. For detailed instructions, please refer to
the CT Clamp manual.
Solar Mode: Activating this option means that the charger will only work with
solar power.
Solar current limit: You can set the minimum remaining current in the solar
system to 7A using the Solar current limit. Then, the charger will work.
Boost Mode: You can turn on the Boost Mode to prioritize the use of solar
energy. When there isn't enough solar energy, power from the grid will be
withdrawn at the same time.
Solar Mode period: You need to manually set the Solar Mode period. During this
time range only, the solar mode will be active.
Attention: It's important to note that the charge using solar will only
start if the surpluses are equal to or more than the solar current limit
and if the charge time is within the solar mode period time.