Service Manual
Dishwasher LP8 850
Service Manual: MS-DW-0071-00-0913 - 9 -
To check the flow meter, use a multimeter in ohm position and observe
the pulses while it turns. If there are not pulses shown in the multimeter,
the flow meter is broken. Do not forget that connections must always be
checked before proceeding with its replacement.
Electric Aquastop
It is located in the water supply hose,
protecting the appliance against water
leaks. It is commanded by the PCB.
The use of this device makes not
necessary the control of the water
inlet with a valve.
In case of a leak of water detected by the floater switch, its valve will be
activated blocking the water supply. The error shown on the display would
be E4.