Service Manual: MS-DW-0071-00-0913 - 15 -
- E6 NTC sensor with open circuit.
This error is detected by the PCB in the test program procedure.
With this error the drain pump will run till the flowmeter keeps stopped
during 2 minutes. After that the dishwasher will stop and the buzzer will
beep during 30 seconds while the error is shown on display.
- E7 NTC sensor with short circuit.
This error is detected by the PCB in the test program procedure.
With this error the drain pump will run till the flowmeter keeps stopped
during 2 minutes. After that the dishwasher will stop and the buzzer will
beep during 30 seconds while the error is shown on display.