end
oe
a
|
are
EEE
|
Channel
3
and
Channel
4
VOLTS/DIV
Switches—.
Select
either
of
two
basic
deflection
factors
for
Channel
3
and
Channel
4.
When
the
VOLTS/DIV
button
light
is
off,
the
deflection
factor
is
0.1
V
per
division
(using
a
X1
probe
or
a
coaxial
cable
input
connection);
when
it
is
on,
the
deflection
factor
is
0.5
V
per
division.
CH
3
and
CH
4
input
Connectors—-Connect
exter-
nal
signals
to
the
inputs
of
Channel
3
and
Channel
4
vertical
attenuators
via
DC
input
coupling
only.
The
input
connectors
are
BNC
with
probe-coding
ring
contacts
(the
same
as
the
Channel
1
and
Chan-
nei
2
connectors).
The
limited
choice
of
deflection
factors
for
the
Channel
3
and
Channel
4
inputs
makes
them
most
useful
for
the
application
of
digital
signal
levels
and
trigger-signal-input
channels.
In
X-Y
mode,
signals
applied
to
either
or
both
input
connec-
tors
may
be
selected
to
provide
a
vertical
deflection
(Y-Axis)
signal.
HORIZONTAL
See
Figure
3-4
for
items
24
through
32.
©
POSITION
Control-—Sets
the
horizontal
position
of
the
waveform
displays
on
the
crt.
Clockwise
rotation
of
the
POSITION
control
will
move
the
display
to
the
right.
X10
MAG
Switch—Horizontally
magnifies
the
por-
tion
of
all
the
normal
sweep
displays
positioned
at
the
center
vertical
graticule
line
by
a
factor
of
10
when
the
X10
MAG
button
light
is
on.
No
action
occurs
in
X-Y
mode.
A
X10
symbol
appears
in
the
readout
on
the
right
side
of
the
A
SEC/DIV
display
in
A
and
ALT
Horizon-
tal
MODE
and
on
the
left
side
of
the
B
SEC/DIV
display
in
B
Horizontal
MODE
when
X10
MAG
is
on.
In
X10
MAG
mode,
the
fastest
display
sweep
speed
is
extended
to
2ns
per
division.
The
crt
SEC/DIV
readout
reflects
the
correct
display
sweep
speed
for
the
X10
MAG
displays
and
the
unmagnified
displays.
MODE
Buttons
(Up-Arrow
and
Down-Arrow)
and
Indicators—
Select
and
indicate
the
operating
mode
of
the
horizontal
deflection
system.
The
Up/Down
MODE
buttons
are
used
to
select
the
desired
mode
of
operation;
the
Horizontal
MODE
indicator
lights
show
the
selected
horizontal
REV
OCT
1986
Controls,
Connectors,
and
Indicators--2246
Operators
deflection
mode.
{Not
all
Menu
Measurement
modes
are
compatible
with
all
horizontal
deflection
modes.
See
Section
6
for
Menu
Measurement
operation.)
A—Horizontal
deflection
occurs
at
a
sweep
speed
determined
by
the
A
SEC/DIV
switch
set-
ting
displayed
in
the
crt
readout.
The
A/B
SELECT
setting
initializes
to
the
A
Trigger
when-
ever
the
A
MODE
is
selected.
ALT—Alternates
between
the
A
Sweep
{with
an
intensified
zone)
and
the
B
Delayed
Sweep.
Both
the
A
and
the
B
SEC/DIV
switch
settings
are
displayed
in
the
crt
readout.
The
A/B
SELECT
setting
initializes
to
the
B
Trigger
whenever
ALT
MODE
is
selected.
The
B
SEC/DIV
switch
setting
is
selectable
in
ALT
Mode,
but
it
cannot
be
set
slower
than
the
A
SEC/DIV
switch
setting.
Attempting
to
do
so
will
switch
both
the
A
and
the
B
SEC/DIV
switch
set-
tings
to
a
slower
sweep
speed.
A
faster
A
SEC/DIV
setting
must
be
set
by
the
A
and
B
SEC/DIV
switch
in
the
A
Horizontal
MODE
before
switching
to
ALT
MODE.
The
B
Sweep
speed
and
the
length
of
the
intensified
zone
are
both
determined
by
the
B
SEC/DIV
switch
setting.
When
the
A
SEC/DIV
and
the
B
SEC/DIV
are
both
set
to
the
same
sweep
speed,
an
intensified
zone
1/100
of
the
A
SEC/DIV
setting
appears
on
the
A
Sweep
and
no
alternate
B
Delayed
Sweeps
are
displayed.
To
display
the
B
Delayed
Sweep
in
ALT
Mode,
set the
B
SEC/DIV
setting
to
a
faster
sweep
speed
that
the
A
SEC/DIV
setting.
B—Horizontal
deflection
occurs
at
a
sweep
speed
determined
by
the
B
SEC/DIV
switch
setting.
The
A/B
SELECT
setting
initializes
to
the
B
Trigger
whenever
the
B
MODE
is
selected.
The
start
of
the
B
Sweep
in
RUNS
AFTER
mode
(or
the
arming
of
the
B
Trigger
in
any
triggered
mode)
is
delayed
from
start
the
of
the
A
Sweep
by
a
time
determined
by
the
setting
of
the
I+
or
DELAY
control.
The
B
SEC/DIV
switch
setting
and
the
Delay
Time
Position
setting
are
displayed
in
the
crt
readout.
A
question
mark
is
displayed
in
front
of
the
Delay
Time
readout
if
the
B
Trigger
MODE
is
not
RUNS
AFTER.
When
a
time
CUR-
SOR
measurement
mode
is
selected
(+
SEC
-l,
l-
1/SEC
I,
or
l-e
PHASE
I)
is
selected,
the
B
Trigger
MODE
switches
to
RUNS
AFTER
so
that
timing
measurements
may
be
made.
X-Y—
The
signal
applied
to
CH
1
ORX
input
connector
produces
the
horizontal
(X-Axis)
deflection.
Signals
applied
to
any