Measurement
Processes
and
Applications-——
2246
Operators
Input
Channel
VOLTS/DIV
Setting
VAR
VOLTS/DIV
To
display
about
3
to
5
divisions
of
signal.
Calibrated
(fully
clockwise
in
detent).
input
Channel
COUPLING
DC
BW
LIMIT
OFF
(button
light
off).
CH
2
INVERT
OFF
(button
light
off).
Horizontal
MODE
A
X10
MAG
Off
(button
light
off).
SEC/DIV
Suitable
sweep
speed
for
the
applied
signai.
Start
of
trace
at
left
graticule
edge.
Set
to
select
the
A
Trigger
control
settings
(button
light
on).
TRIGGER
MODE
AUTO
LEVEL
TRIGGER
SOURCE
VERT
TRIGGER
COUPLING
DC
HOLDOFF
MIN
(fully
counterclockwise)
MEASUREMENT
All
off
(press
MODES,
TRACKING
CLEAR
DISPLAY
CURSORS
and
three
times
to
MENUS
ensure
all
off).
Horizontal
POSITION
A/B
SELECT
3.
Press
the
CH1/CH2
VOLTMETER
button
to
call
up
the
selection
menu
and
select
the
+PEAK
choice.
Any
of
»
the
page
one
choices
may
be
selected
as
required
for
the
waveform
measurement
wanted.
NOTE
Depending
on
the
way
the
CONFIGURE
choices
of
the
SERVICE
menu
have
been
made,
the
menu
will
either
go
off
when
the
measurement
selection
is
made
or
it
will
stay
on.
If
the
menu
remains
on,
press
the
CLEAR
DISPLAY
button
once
to
remove
it
from
the
display.
See
the
"SERVICE
MENU”
discus-
sion
in
this
section
for
further
details.
l
4.
The
TRACK
MEASMT
cursor
may
be
displayed
with
the
waveform.
Pressing
CLEAR
DISPLAY
in
the
initial
setup
removes
the
measurement
tracking
cursor
from
the
display
but
does
not
disable
the
feature
once
it
has
been
enabled;
and
the
next
time
a
CH1/CH2
VOLTMETER
measurement
mode
is
called
for,
the
measurement
track-
ing
cursor
is
again
displayed.
5.
Press
the
CURSORS
button
and
display
page
2
of
the
menu
by
selecting
the
(TO
AUTO
TRACKING
MENU)
6-10
choice.
Of
the
three
features
available
in
page
2,
select
both
TRACK
MEASMT
and
TRACK
rh.
Menu
labels
are
UNDERLINED
when
the
function
is
enabled.
The
TRACK
rh
cursor
is
especially
useful
for
providing
feedback
to
the
user
about
de
offset
of
the
signal
from
ground
level.
NOTE
In
this
menu,
the
select
buttons
toggle
the
choices
on
and
off
with
each
press,
and
all
three
choices
may
be
selected
(but
not
all
displayed
together
because
only
two
cursors
are
allowed).
Also,
press-
ing
CLEAR
DISPLAY
(as
many
as
three
times
may
be
necessary)
does
turn
off
the
TRACK
TRIG
LVL
and
TRACK
rh
choices.
6.
Press
either
MENU
OFF
(in
the
menu
selection
list)
or
CLEAR
DISPLAY
(once)
to
remove
the
AUTO
TRACK-
ING
menu
from
the
display.
NOTE
If
CH1/CH2
VOLTMETER
PK-PK
measurement
is
selected,
two
TRACK
MEASMT
cursors
are
required;
therefore,
the
TRACK
rh
cursor
will
not
be
displayed,
7.
See
Figure
6-7.
The
test
signal
used
for
the
example
has
a
de
offset
(as
shown
by
the
position
of
the
TRACK
rh
cursor),
and
+
PEAK
value
(peak
ac
+
dc)
as
indicated
by
the
voltage
readout.
GATED
VOLTAGE
MEASUREMENT
If
you
need
to
track
the
+PEAK,
—PEAK,
or
PK-PK
voltage
of
a
selected
portion
of
a
waveform,
that
portion
can
be
defined
using
the
GATED
MEASUREMENTS
avail-
able
in
page
2
of
the
CH1/CH2
VOLTMETER
menu.
The
general
steps
given
is
the
previous
+PEAK
Voltage
Measurement
procedure
are
used
for
this
function
also.
Set
up
all
the
controls
and
apply
the
signal
to
be
meas-
ured
in
the
same
way;
but,
after
pressing
the
CH1/CH2
VOLTMETER
button,
select
the
(TO
GATED
MEASMT
MENU)
choice.
After
that,
follow
these
additional
steps
to
make
the
gated
measurement.
1.
Select
GATED
+PEAK
measurement
mode.
The
menu
will
be
removed
(if
configured
to
do
so),
and
any
enabled
tracking
cursors
will
be
displayed.
If
none
are
enabled
in
page
2
of
the
CURSORS
menu,
none
will
be
displayed.

Questions and Answers: