EasyManua.ls Logo

Tektronix 2247A

Tektronix 2247A
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
i
i
£
ji
ES
Performance
Check
Procedure
f.
Set
bottom
of
the
signal
to
bottom
graticule
line.
g.
CHECK—the
signal
amplitude
Is
between
1.9
and
2.1
divisions.
h.
Repeat
the
procedure
for
CH
2.
9.
CH
1
and
CH
2
Vertical
Deflection
Accuracy
a.
Set
CH
2
VOLTS/DIV
to
2
mV.
b.
Set
calibration
generator
to
Std
Ampl
output,
10
mV.
c.
Positlon
the
trace
two
graticule
lines
below
the
center
horizontal
graticule
line.
d.
CHECK
—all
positions
of
the
VOLTS/DIV
settings
for
correct
signal-to-
graticule
accuracy,
using
the
settings
In
Table
7-2
for
the
checks.
Table
7-2
Signal-to-Gratlcule
Accuracy
VOLTS/DIV
Std
Ampl
Deflection
Accy
Setting
Setting
(in
divisions)
2mVv
10
mV
4.90
to
5.10
5
mV
20
mV
3.92
to
4.08
10
mV
50
mV
4.90
to
5.10
20
mv
100
mV
4.90
to
5.10
50
mv
200
mV
3.92
to
4.08
0.1V
500
mV
4.90
to
5.10
0.2Vv
1Vv
4.90
to
5.10
0.5
Vv
2Vv
3.92
to
4.08
1Vv
5V
4.90
to
5.10
2Vv
10
V
4.90
to
5.10
5
Vv
20
V
3.92
to
4.08
2247A
Operators
7-15