Fig. 17: Inserting the SIM in the internal tray
4.4 RST button
The Regesta Smart PRO features an external button labeled “RST” on its connector panel. This button serves two
functions:
Firstly, it can be pressed to initiate a reboot of the device.
Secondly, it is used to restart the device with its default configuration. The default configuration assigns IP
192.168.1.1 to the WAN port.
To prevent accidental activation, the external button is securely protected. It requires the use of a sharp-pointed ob-
ject to activate it.
4.4.1 Restarting the device
To restart the device, please follow these steps:
(1) Press the RST button. The device will restart, the ON LED will light up in green and all other LEDs (SW, S, C, L,
LAN, WAN, SFP, S1 and S2) should be turned off.
(2) Release the RST button once all LEDs except the ON LED have switched off.
(3) The device will now fully restart.
4.4.2 Default configuration
Follow these steps to use the RST button and restore the device to its default configuration:
(1) Press the RST button. The device will restart, the ON LED will light up in green and all other LEDs (SW, S, C, L,
LAN, WAN, SFP, S1 and S2) should be turned off.
(2) Continue pressing the RST button until the S LED flashes in orange, the ON LED will light up in green and all
other LEDs should be turned off. These changes indicate that the device's configuration has been reset to its
default settings.
(3) Release the RST button to allow the device to finish restarting.
(4) With the device now restored to its default configuration, you can access it using IP address 192.168.1.1. Re-
member that it can be accessed from the WAN port.
4.5 Dying gasp alarm
The Regesta Smart PRO offers the option to add a board that enables an alarm to be triggered in case of a power
outage or if the power supply cable is removed.
With a power consumption of only 10W, the device remains powered for up to 6 seconds, allowing the alarm to be
transmitted through any active interface.
This alarm, referred to as GW.075, can be sent as an Event, SNMP-TRAP, or Syslog through the Event Logging
System (ELS).
To configure this functionality, follow these steps:
Teldat S.A.
4 Connecting the Router
Regesta Smart PRO 29

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Teldat Regesta Smart PRO and is the answer not in the manual?

Teldat Regesta Smart PRO Specifications

General IconGeneral
BrandTeldat
ModelRegesta Smart PRO
CategoryNetwork Hardware
LanguageEnglish