67www.behnke-online.de
GB
Instructions for Behnke SIP 2.0
Camera configuration
14.2. Reset to default settings
(For 20/50 series camera modules, remove the camera cover before resetting)
The camera may be returned to default
settings after initialisation (approx. 2 minutes
after power on) when the red LED
is perma-
nently illuminated.
Please press the reset button
and keep it
pressed for at least three seconds.
The red LED
starts flashing upon pressing
the reset button and increases the flashing
intervals once the button is let go. Afterwards,
the camera will reboot.
As soon as the red indicator LED
is once
again permanently illuminated, the camera
has been returned to its default settings and
is ready to go.