1-40. “Passive Act”: This function ensures safe operations, including
when there are disturbances that may affect the
normal operating conditions. This assures that when
the machine operates, the control is not subject to
temporary and unexpected stops. Possible short
interferences are bypassed. The passive act can be
selected in 2 modes as below.
a. “Power Off”: If the interferences are larger than the pre-set time,
the receiver will turn off all the relays under
“Normal” function and “Control by EMS” including
MAIN relay. The receiver must be restart to operate
again, follow the “Power On” procedure to restart the
system.
b. “Relay Off”: If the interferences are larger than the pre-set time,
the receiver will turn off all the relay under “Normal”
function except the MAIN relay.
1-41. “Auto Off (RX)”: If select “YES”, the Receiver MAIN relay will be
turned off automatically after a given idle time.
Normally, this function is cooperated with “NO”
mode of “Continuous (TX)” to prevent any
unintentional radio.
1-42. “Auto Off Time (RX)”: This function is available when “YES”
mode of “Auto Off (RX)” is selected. It
allows you to select the time to execute
“Auto Off (RX)” or you can select “Not-
Execute”.
23