Thermostatic control
Thermostatic control allows you to keep the indoor temperature at a steady level. Just send
the temperature value in the command.
HouseControl cannot exceed the maximum temperature limit programmed in the heating
system of your house. HouseControl reads its own T1 temperature sensor and turns heater on
or off based on the read information. Command HEATER returns the current setting.
Manual control
You can turn heating on if you do not have your mobile phone at hand by pressing the manual
heating control switch. If manual control is on, you cannot control heating from your mobile
phone until you switch manual control off from the right-hand side switch.
Temperature alarms
HouseControl monitors indoor and outdoor temperatures, and alarms you if either temperature
rises too high or drops too low. The temperature alarm limits are adjustable.
When using thermostatic control, you must set the temperature alarm limits at least three
degrees lower and higher than what the normal temperature range is.
The water pipe temperature alarm is not enabled by default. Send command #TEMP3 ON to
your HouseControl if you have T3 sensor connected and want to start receiving alarms from
this sensor. You can disable the T3 sensor with command #TEMP3 OFF. The device will
respond with messages starting with #I18, you can ignore these.
HEATER 7
HEATER 7
HEATER ON / OFF / nn
This turns the heater connected to HouseControl on or off
or to nn degrees.
T?
This returns the alarm limits and the name of the sensor.
T?
T2 –30 +50 OUT
T3 +8 +45 WATER
T1 x y nn
This sets alarm limits and name for the indoor temperature sensor.
x = low limit, y = high limit, nn = name (for example, WATER).
Manual heating control on (red light) and off switch.
This turns siren on or off. The siren is sounded
automatically in some cases.