What to do if my Telguard TG-7FP has RFC Radio Failure?
- JJames HollandAug 2, 2025
Wait for RFC restoral.
What to do if my Telguard TG-7FP has RFC Radio Failure?
Wait for RFC restoral.
What to do if my Telguard Security System has NSC No Service?
Continue to validate signal strength; the NSC will restore when the signal returns.
What to do if my Telguard TG-7FP has PPF Panel Presence Fail?
Wait for PPF restoral.
What does 'Disable TX' mean for my Telguard Security System?
TX capability is disabled until further notice. The TG-7FP can still receive radio signals from the TCC.
How to solve LPF Low Power Failure on Telguard TG-7FP Security System?
Verify the connection from the panel aux power and correct it.
What is the reason for DTF Dial Tone Failure in my Telguard TG-7FP?
The cause is an internal dial tone voltage supply circuit failure.
What does Automatic Self-Test mean for Telguard TG-7FP Security System?
Self-test information is sent to central station via TCC, then the system returns to a ready state.
Describes the TG-7FP's function as a sole path or primary/secondary path cellular communicator.
Highlights the TG-7FP's ability to support various alarm communication formats automatically.
Explains continuous cellular path monitoring and failure conditions like NSC and RFC.
Defines Panel Presence Failure, its indication via LED, and requirements for enabling.
Explains how to enable and verify link supervision for UL/ULC compliance.
Describes the TG-7FP's rating for single/dual line transmission in UL Burglary Systems.
Details power-related conditions including Low Power Failure, Dial Tone Failure, and Catastrophic Failure.
Explains the need for a dealer account and how to establish it via the Telguard website.
Lists required parts shipped with the TG-7FP and essential installation test tools.
Summarizes the essential steps for installing the communicator in the correct order.
Details the process of registering the TG-7FP for Telguard service via the dealer portal.
Explains specific features like Link Supervision and End-to-End Acknowledgment for fire applications.
Illustrates various connection scenarios for the TG-7FP with alarm panels.
Details the connection setup when TG-7FP is the only communication path.
Explains the meaning of LED indications during normal operation for system status.
Discusses recommended signal strength for reliable TG-7FP operation in fire systems.
Explains how to configure the alarm panel for sole path communication, disabling the second Telco connection.
Details the interface for digital dialers and power specifications like current draw.
Specifies electrical ratings for wiring, relays, trip input, and system fault impedance.
Covers FCC compliance, supported bands, physical size, and operating environment.
| Communication | Cellular |
|---|---|
| Power Supply | 12V DC |
| Standby Current | 50 mA |
| Battery Backup | Yes |
| Inputs | 4 |
| Zones | 8 |
| Device Type | Alarm communicator |