HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved. Page 225 of
229
+STKTR – SIMTOOLKIT Terminal Response
- 35: user cleared down call before connection or network release
- 36: action in contradiction with the current timer state
- 37: interaction with call control by SIM, temporary problem
- 38: launch browser generic error code
- 48: command beyond ME’s capabilities
- 49: command type not understood by ME
- 50: command data not understood by ME
- 51: command number not known by ME
- 52: SS return error
- 53: SMS RP-ERROR
- 54: error, required values are missing
- 55: USSD return error
- 56: MultipleCard commands error, if class “a” is supported
- 57: interaction with call control by SIM or MO short message control by SIM,
permanent problem
- 58: bearer independent protocol error (if class “e” is supported)
AT+STKTR=?
Test command returns the supported proactive command list.
3.5.5.5.4. SIMTOOLKIT Envelope command - +STKENV
+STKENV – SIMTOOLKIT Envelop command
AT+STKENV=<envelo
pe_cmd>,<optional_EN
V_data>
This command allows to send a SIM -APPL-TK envelope command. Set command allows
sending a SIM -APPL-TK envelope command. If fails returns CME ERROR :<error>
Syntax of Command:
AT+STKENV=<envelope_cmd>,<optional_ENV_data>
AT+STKENV=214,7,<language>
AT+STKENV=214,8,<cause >
AT+STKENV=211,<item_id>,<help_requested>
Parameters:
<envelope_cmd> supported envelope commands:
- code 211 (hexa D3): menu selection (needs <item identifier>)
- code 214 (hexa D6): Event download (only one event can be included in the <event_list>)
<optional_ENV_data> indicates command code related parameters as follows:
- for code 211 (hexa D3): <item identifier>
- for code 214 (hexa D6): <event list>
Where :
<cause> may be:
- 00: User Termination
- 01: Error Termination
<item_id> item identification