1.
INSTALLATION
11.
POWER
SUPPLY
JUPITER
requires
a
source
of
well-
filtered
and
regulated
DC
voltage.
The
supply
voltage
can
range
from
+12.0
to
+15.0
VDC
but
+13,8
VDC
is
optimum
and
recommended.
Тһе
power
source
must
be
capable
of
20-ampere
peaks.
If
you
wish
to
run
JUPITER
to
its
full
capability
on
digital
modes,
the
current
capacity
must
apply
at
100%
duty
cycle,
and
you
will
need
to
direct
a
cooling
air
stream
(from
a
fan)
at
the
heat
sink.
NOTE:
ALWAYS
ENABLE
THE
POWER
SOURCE
FIRST
AND
THEN
THE
TRANSCEIVER.
IF
THE
DC
SOURCE
IS
SUPPORTED
BY
A
GENERATOR
OR
ALTERNATOR,
ALWAYS
TURN
OFF
THE
TRANSCEIVER
BEFORE
THE
EQUIPMENT
IS
STARTED
OR
SHUT
OFF,
THESE
RECHARGING
DEVICES
OFTEN
GENERATE
LARGE
VOLTAGE
SPIKES
THAT
CAN
DAMAGE
THE
TRANSCEIVER.
The
TEN-TEC
Model
963
power
supply
is
specifically
designed
for
this
service.
This
supply
has
built-in
overcurrent
protection
and
all
the
necessary
RF
bypassing.
The
2-pin
ОС
connector
оп
the
rear
panel
of
JUPITER
is
polarized
to
permit
attaching
the
mating
plug
in
only
the
correct
way.
Determine
the
correct
orientation
and
plug
the
power
cable
into
JUPITER.
If
you
plan
to
use
a
power
source
other
than
Model
963,
we
recommend
the
pre-assembled
DC
power
cord
(#86095)
that
we
supply
with
the
963.
Older
model
Ten-Tec
power
supplies
with
4-pin
connectors
74269
Second
Printing
Model
538
JUPITER
30
August,
2001
require
the
model
306
4-pin
to
2
pin
adapter.
RED
(+)
REGULATED
13.8
VDC,
20
AMP
POWER
SUPPLY
BLACK
(-)
Figure
1-1
Power
Supply
Connections
We
have
also
included
two
spare
connector
pins
(#41020)
and
а
connector
shell
(#35165)
for
building
your
own
cord.
Be
sure
to
use
no
less
than
14
gauge
stranded
wire
for
these
connections
because
of
the
high
current
demand
on
transmit.
12.
ANTENNA
The
transmitter
is
protected
against
damage
from
brief
load
impedance
mismatches
ranging
from
a
dead
short
to
an
open
circuit.
Operation
at
or
near
full
power
is
possible
with
an
unbalanced
(coax
feed)
load
impedance
between
25
and 100
ohms
(approximately
2:1
SWR).
Antennas
with
higher
SWR
require
an
external
antenna
tuner,
as
do
single
wire
and
balanced
feedline
types.
An
50-239
connector
on
the
rear
panel
connects
the
antenna
to
the
transceiver.
1.3.
EXTERNAL
ЗРЕАКЕК
Note:
JUPITER
provides
a
connection
for
an
ungrounded
external
speaker.
JUPITER’s
audio
power
amplifier
IC
uses
a
full-bridge
circuit.
This
connects
the
speaker
terminals
as
a
balanced
load
between
two
amplifiers
driven
in
push-pull.
While
the
circuit
floats
both
sides
of
the
speaker
off
ground,
it
maximizes
the
undistorted
output
power
from
a
single-ended
supply.